YOKOGAWA Admag TI Series User Manual

YOKOGAWA Admag TI Series User Manual

Axg magnetic flowmeter, fm (usa) explosion protection type
Hide thumbs Also See for Admag TI Series:

Advertisement

User's
Manual
ADMAG TI Series
AXG Magnetic Flowmeter
FM (USA) Explosion Protection Type
IM 01E21A03-01EN
IM 01E21A03-01EN
1st Edition

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Admag TI Series and is the answer not in the manual?

Questions and answers

Summary of Contents for YOKOGAWA Admag TI Series

  • Page 1 User’s Manual ADMAG TI Series AXG Magnetic Flowmeter FM (USA) Explosion Protection Type IM 01E21A03-01EN IM 01E21A03-01EN 1st Edition...
  • Page 2: Table Of Contents

    Technical Data ...................... 3 Cable Entry ......................7 Installation ......................7 Operation ......................12 Maintenance and Repair ................... 12 Specific Condition of Use ................. 12 Revision Information 1st Edition: Oct. 2019 (KP) IM 01E21A03-01EN All right Reserved Copyright © 2019. Yokogawa Electric Corporation...
  • Page 3: Introduction

    IM 01E21A21-01Z1 (Read Me First). These documents can be downloaded from the website of YOKOGAWA. To ensure correct NOTE use of the product, read these manuals thoroughly and fully understand how to operate the product A NOTE sign denotes information necessary before maintaining it.
  • Page 4  Regarding This User’s Manual  Trademark • This manual should be provided to the end • All the brands or names of Yokogawa user. Electric’s products used in this manual are • The contents of this manual are subject to either trademarks or registered trademarks of change without prior notice.
  • Page 5: Explosion Protection Type

    <2. Explosion Protection Type> Explosion Protection Type Technical Data WARNING Applicable Standard: FM 3600, FM3610, FM3615, FM3616, FM3810, AXG### magnetic flowmeter (Integral Flowmeter ANSI/UL UL 50E, NEMA 250, ANSI/UL 60079-0, or Remote Sensor), and AXG4A Remote ANSI/UL 60079-7, ANSI/UL 60079-11, ANSI/UL Transmitter are products which have been 60079-18, ANSI/UL 61010-1, ANSI/UL 61010-2-30 certified as explosion protection type products.
  • Page 6 <2. Explosion Protection Type> Remote Sensor Remote Transmitter Explosionproof Explosionproof (Explosion Protection Code: FF2) (Explosion Protection Code: FF2) • Type of Protection: • Type of Protection: CL I/II/III GP ABCDEFG CL I/II/III GP ABCDEFG IS CL I GP ABCD • Enclosure: Type 4X T6...T3 •...
  • Page 7 <2. Explosion Protection Type> Table 2.2 Ambient Temperature and Process Temperature Ambient Temperature Maximum Surface Process Table No. Temperature Class Temperature Temperature T75°C -40°C to +75°C T90°C -40°C to +90°C -40°C to +60°C T120°C -40°C to +120°C T130°C -40°C to +130°C -40°C to +45°C T75°C -40°C to +50°C...
  • Page 8 <2. Explosion Protection Type> Fluid Temperature and Pressure: PFA Lining, Remote Sensor and Integral Flowmeter (high pressure type, ASME Class 600 flange) The figure shows the usable range of the sensor Pressure in each specification. It is also limited by the MPa (psi) flange pressure rating of the process connection.
  • Page 9: Cable Entry

    <2. Explosion Protection Type> Cable Entry The grounding terminals are located on the inside and outside of the terminal area. The type of cable entry is stamped near the cable Connect the cable to the grounding terminal in entry port according to the following codes. accordance with wiring procedure (a) or (b).
  • Page 10 <2. Explosion Protection Type> Read the Control Drawing. All wiring shall comply with local installation requirements. • Integral Type Flowmeter (Explosion Protection Code: FJ2) F0213.ai IM 01E21A03-01EN...
  • Page 11 <2. Explosion Protection Type> • Remote Type Flowmeter (Explosion Protection Code: FJ2) F0214.ai IM 01E21A03-01EN...
  • Page 12 <2. Explosion Protection Type> • Integral Type Flowmeter (Explosion Protection Code: FT2) F0215.ai IM 01E21A03-01EN...
  • Page 13 <2. Explosion Protection Type> • Remote Type Flowmeter (Explosion Protection Code: FT2) F0216.ai IM 01E21A03-01EN...
  • Page 14: Operation

    Remote Sensor • Take care the following warning marking “OPEN CIRCUIT BEFORE REMOVING COVER”. Maintenance and Repair Only personnel authorized by Yokogawa Electric Corporation can repair the equipment Specific Condition of Use • In the case the electrodes and/or grounding rings...
  • Page 15: Revision Information

    Revision Information Title : ADMAG TI Series  AXG Magnetic Flowmeter FM (USA) Explosion Protection Type Manual No. : IM 01E21A03-01EN  Edition Date Page Revised Item Oct. 2019 — New Publication IM 01E21A03-01EN...

Table of Contents