(Read Me First (Optional Code EC)). These part or the entire product. documents can be downloaded from the website of YOKOGAWA. To ensure correct use of the product, read these manuals thoroughly and fully understand IMPORTANT how to operate the product before maintaining it. For...
Page 4
Regarding This User’s Manual Trademark • This manual should be provided to the end • All the brands or names of Yokogawa user. Electric’s products used in this manual are • The contents of this manual are subject to either trademarks or registered trademarks of change without prior notice.
<2. Explosion Protection Type> Explosion Protection Type Technical Data WARNING Applicable Standard: EN 60079-0: 2012+A11:2013, EN 60079-1: 2014, AXG### and AXW### magnetic flowmeter EN 60079-7: 2015, EN 60079-11: 2012, (Integral Flowmeter and Remote Sensor), and EN 60079-31: 2014 AXG4A and AXW4A Remote Transmitter are Certificate: products which have been certified as explosion FM 17ATEX0031X...
Page 6
<2. Explosion Protection Type> Remote Sensor Remote Transmitter • Type of Gas Atmosphere Protection • Type of Gas Atmosphere Protection Group: II Group: II Category: 2G Category: 2G Type of Protection: Type of Protection: Ex db eb ia IIC T6…T3 Gb Ex db IIC T6 Gb •...
Page 7
<2. Explosion Protection Type> Table 2.2 Ambient Temperature and Process Temperature Ambient Temperature Maximum Surface Process Table No. Temperature Class Temperature Temperature T75°C -40°C to +75°C T90°C -40°C to +90°C -40°C to +60°C T120°C -40°C to +120°C T130°C -40°C to +130°C -40°C to +45°C T75°C -40°C to +50°C...
<2. Explosion Protection Type> Cable Entry Installation The type of cable entry is stamped near the cable Read the Installation Manual, IM 01E22A01-01EN entry port according to the following codes. (for AXG### and AXG4A) or IM 01E24A01-01EN (for AXW### and AXW4A), for basic installation Marking Screw Size procedure.
UTES BEFORE OPENING”. Remote Sensor • Take care the following warning marking “DE-ENERGIZING BEFORE OPENING”. Maintenance and Repair Only personnel authorized by Yokogawa Electric Corporation can repair the product. For maintenance of explosion protection type product, read maintenance manual, IM 01E22A01- F0205.ai...
<2. Explosion Protection Type> Name Plate Example for name plates of Integral Flowmeter, Remote Sensor or Remote Transmitter. Integral Flowmeter F0207.ai Remote Sensor F0208.ai Remote Transmitter F0209.ai - MODEL: Specified model code - SUFFIX: Suffix codes of the model code - STYLE: Specified style code - SIZE: Nominal size of apparatus - METER FACTOR:...
<2. Explosion Protection Type> Specific Condition of Use Integral Flowmeter, Remote Sensor and Remote Transmitter • Electrostatic charges on the non-metallic parts (excluding glass parts) or coated parts of the product shall be avoided. • The flameproof joints differ from the standard values in EN 60079-1.
Revision Information Title : ADMAG TI Series AXG and AXW Magnetic Flowmeter ATEX Explosion Protection Type Manual No. : IM 01E21A03-02EN Edition Date Page Revised Item Oct. 2018 — New Publication IM 01E21A03-02EN...