Sign In
Upload
Manuals
Brands
YOKOGAWA Manuals
Measuring Instruments
ADMAG TI Series
YOKOGAWA ADMAG TI Series Manuals
Manuals and User Guides for YOKOGAWA ADMAG TI Series. We have
10
YOKOGAWA ADMAG TI Series manuals available for free PDF download: User Manual, Installation Manual, Read Me First
YOKOGAWA ADMAG TI Series User Manual (306 pages)
FOUNDATION Fieldbus Communication Type
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
1 Introduction
8
For Safe Use of Product
11
Warranty
13
2 About Fieldbus
14
Overview
14
Internal Structure
14
System/Network Management VFD
14
Function Block VFD
14
Logical Structure of each Block
16
3 Getting Started
17
Connection of Devices
17
Host Setting
19
Bus Power on
20
Integration of DD
21
Reading the Parameters
21
Continuous Record of Values
21
Generation of Alarm
21
4 Configuration
22
Network Design
22
Network Definition
23
Definition of Combining Function Blocks
25
Setting Tag and Address
26
Communication Setting
27
VCR Setting
27
Function Block Execution Control
28
Mode Transition
28
VFD Parameter Configuration
29
Link Object
29
Alert Object
30
Trend Object
31
View Object
31
Function Block Parameters
47
5 Functions
51
Basic Settings
51
Overview
51
Connection of Process Value to AI Function
51
Display of the Process Value
54
Engineering Unit Setting
56
Span Setting
57
Damping Time Constant Setting
58
Low-Cut Function Setting
60
Sensor's Nominal Size Setting
62
Density Setting
63
5.1.10 Temperature Setting
64
Zero Adjustment
65
Totalization Function
67
Totalized Value and Unit Setting
67
Totalized Value Display and Totalization Counter Function
67
Totalization Switch Function
68
Operation of Totalizer Function at Alarm Occurrence
69
Start/Stop Setting for Totalization Function
69
Totalization Direction Setting
70
Totalized Value Reset/Preset Function
70
Limit Switch Function
72
Limit Switch
72
Connection of Contact Point Output to DI Function
80
Inputting External Temperature
82
Auxiliary Calculation Function
83
Fluid Flow Direction Setting
83
Rate Limit Function Setting
83
Pulsing Flow Support Function Setting
86
Power Frequency Synchronization Setting
86
Density Correction Calculation
87
Calorie Calculation
89
0% Signal Lock
90
Alarm
91
Alarm Display
91
Errors and Countermeasures
91
Operation at the Time of Error
100
Alarm Display Setting
106
Alarm Record Function
107
Alarm Mask Function
108
Display
113
Language Setting
113
Display Item Setting
114
Decimal-Point Position Setting
115
Display Line Count and Scroll Settings
116
Trend Graph Setting
117
Other Settings
120
Microsd Card Setting
123
Device Information
125
Order Information
125
Device Revision
126
Memo Function
127
Self-Check Function
128
Types of Diagnosis Functions
128
Alarm High/Low Limit Function
128
Electrode Adhesion Detection
130
Sensor Empty Check
132
Wiring Connection Diagnosis
132
Verification (Device Health Diagnosis) Function
134
Electrode Insulation Deterioration Diagnosis (Only Available for AXG, Not for AXW)
137
Diagnosing Flow Noise (Only Available For Axg, Not For Axw)
138
Diagnosing Low Conductivity (Only Available for AXG, Not for AXW)
139
5.9.10 Coil Insulation Diagnosis
140
Other Setting
141
Test Mode
142
5.10.1 Test Mode Setting
142
5.10.2 Test Value Setting
143
5.10.3 Test 2 Mode
143
5.10.4 Test Mode Auto Reset
144
Event Management Function
145
Storing Parameter (Backup)
145
Restore/Duplicate Parameter
150
Backup and Restore Parameters
155
Data Logging Function
158
Write Lock Function
161
Simulation Function
163
Pulse Output, Frequency Output, and Status Output
165
5.14.1 Outputs of I/O2 Terminals
165
5.14.2 Alarm Output Function
165
5.14.3 Pulse Width Setting
166
5.14.4 Active Direction Setting
167
5.14.5 Pulse Rate Setting
167
5.14.6 Frequency Output Range Setting
169
5.14.7 Status Output Function Setting
169
6 Parameter Lists
170
Resource Block
170
Sensor Transducer Block
178
Diagnosis Transducer Block
190
Display Transducer Block
197
Maintenance Transducer Block
203
AI Function Block
211
DI Function Block
215
MAO Function Block (Only AXG)
218
Unit and Code
220
7 Parameter Menu Tree
221
Display Menu Tree
221
Appendix 1. Application, Setting and Change of Basic Parameters
237
A1.1 Applications and Selection of Basic Parameters
237
Setting and Change of Basic Parameters
238
A1.3 Setting the AI Function Block
239
A1.4 Setting the Integrator (IT) Function Block
240
A1.5 Setting the DI Function Block
241
Appendix 2. Integrator (IT) Block
242
A2.1 Schematic Function Diagram of Integrator Block
242
Input Process Section
243
A2.2.1
243
Determining Input Value Statuses
243
A2.2.2
244
Converting RATE
244
A2.2.3
244
Converting ACCUM
244
A2.2.4 Determining the Input Flow Direction
245
A2.3 Adder
245
A2.3.1 Status of Value after Addition
245
A2.3.2 Addition
245
A2.4 Integrator
246
A2.5 Output Process
247
A2.5.1 Status Determination
247
A2.5.2 Determining the Output Value
248
A2.5.3 Mode Handling
249
A2.6 Reset Processing
250
A2.6.1 Reset Trigger
250
A2.6.2 Reset Timing
250
A2.6.3
251
Reset Process
251
A2.7 List of Integrator Block Parameters
252
Appendix 3. Arithmetic (AR) Block
256
A3.1 Functional Block Diagram
256
A3.2 Input Section
257
A3.2.1 Main Inputs
257
A3.2.2 Auxiliary Inputs
258
A3.2.3 Input_Opts
258
A3.2.4 Relationship between the Main Inputs and PV
259
A3.3 Computation Section
260
A3.3.1 Computing Equations
260
A3.3.2 Compensated Values
261
A3.3.3 Average Calculation
261
A3.4 Output Section
261
A3.4.1 Mode Handling
262
A3.4.2
263
Status Handling
263
A3.5 List of the Arithmetic Block Parameters
264
Appendix 4. Link Master Functions
267
A4.1 Link Active Scheduler (LAS)
267
A4.2 Link Master (LM)
267
A4.3 Transition of LM Function
268
A4.4 LM Functions
270
A4.4.1
270
LM Function List
270
A4.5 LM Parameters
271
A4.5.1
271
LM Parameter List
271
A4.5.2
273
Descriptions for LM Parameters
273
A4.6 Faqs
277
Appendix 5. PID Block
279
A5.1 Functional Block Diagram
279
A5.2 Functions of PID Block
280
A5.3 Parameter List of PID Block
281
A5.4 PID Computation Details
283
A5.4.1 Proportional Derivative Leading Type PID Control Algorithm (I-PD)
283
A5.4.2 PID Control Algorithm Parameters
284
A5.5 Control Output Action
284
A5.5.1 Velocity Type
284
A5.6 Direction of Control Action
284
A5.7 Control Action Bypass
285
A5.8 Feed-Forward
285
A5.9 Block Modes
286
A5.9.1 Mode Transitions
286
A5.10 Bumpless Switching
287
A5.11 Setpoint Limiter
287
A5.11.1 When PID Block Is in Auto Mode
287
A5.11.2 When PID Block Is in Cas or Rcas Mode
287
A5.12 External-Output Tracking (LO)
288
A5.13 Measured-Value Tracking
289
A5.13.1 Control_Opts
289
A5.14 Initialization and Manual Fallback (Iman)
290
A5.14.1 Iman Condition
290
A5.14.2 Establishment of Iman Condition
290
A5.15 Manual Fallback
290
A5.15.1 Condition of man Fallback
290
A5.15.2 Specification Of Man Fallback
290
A5.15.3 Status_Opts
290
A5.16 AUTO Fallback
291
A5.16.1 Condition of AUTO Fallback
291
A5.16.2 Specification Of Auto Fallback
291
A5.17 Mode Shedding Upon Computer Failure
291
A5.17.1 Shed_Opt
292
A5.18 Alarm Processing of Block
293
A5.18.1 Block Alarm (BLOCK_ALM)
293
A5.18.2 Process Alarms
293
A5.19 Example of Block Connections
294
Appendix 6. Software Download Function
295
A6.1 Benefits of Software Download Function
295
A6.2 Specifications of Software Download Function
295
A6.3 Preparations for Software Downloading
296
A6.4 Software Download Sequence
296
A6.5 Download Files
297
A6.6 Steps after Activating a Field Device
298
A6.7 Troubleshooting
299
A6.8 Maintenance Block's Parameters Relating to Software Download
300
A6.9 System/Network Management VFD Parameter Related to Software Download
302
A6.10 Comments on System/Network Management VFD Parameters Relating to Software Download
304
Revision Information
306
Advertisement
YOKOGAWA ADMAG TI Series Installation Manual (69 pages)
Magnetic Flowmeter, Size: 25 to 400 mm 1 to 16 in.
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Table of Contents
1
1 Introduction
2
For Safe Use of Product
4
3 Installation
4
Warranty
7
Combination for Remote Sensor and Remote Transmitter
7
2 Receiving and Storage
8
Model and Specifications Check
8
Storage Precautions
9
Piping Design Precautions
10
Handling Precautions
12
General Precautions
12
Flowmeter Piping
13
Integral Flowmeter and Remote Sensor Installation
14
Size 25 to 200 MM (1 to 8 In.), Wafer Type
14
Size 25 to 400 MM (1 to 16 In.), Flange Type
19
Gasket Size(Customer Pipe)
25
Remote Transmitter Installation
26
Installation Location
26
Mounting of AXW4A Transmitter
26
Mounting of AXG1A Transmitter
26
Mounting of AXFA11 Transmitter
27
Changing Direction of Cable Entry
27
Changing Direction of Display Unit
28
4 Wiring
30
Wiring Precautions
30
Cables
31
Cable Entries
32
Connecting to External Products of Integral Flowmeter and Remote Transmitter
36
Connecting to Remote Sensor and Remote Transmitter (Sensor Side)
43
Input and Output
46
5 Basic Operating Procedures
49
Operation by Display Unit
49
Display and Basic Configuration
49
Display Mode and Setting Mode
52
Parameter Setting from Display Panel
53
Microsd Card Setting
54
BRAIN Configuration Tool
55
HART Configuration Tool
55
Modbus Configuration Tool
56
FOUNDATION Fieldbus Configuration Tool
57
6 Operation
58
Pre-Operation Zero Adjustment
58
Zero Adjustment from Display Unit
58
Hardware Switch Setting
59
7 Errors and Countermeasures (Display Unit)
64
YOKOGAWA ADMAG TI Series User Manual (16 pages)
AXG Magnetic Flowmeter EtherNet/IP Communication Type
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
1
1 Introduction
2
For Safe Use of Product
2
Warranty
4
Combination for Remote Sensor and Remote Transmitter
4
2 Receiving and Storage
5
Model and Specifications Check
5
Storage Precautions
5
3 Installation
6
4 Wiring
7
Wiring Precautions
7
Cables
7
Recommended Cable for Ethernet/Ip Communication
7
Cable Entries
7
Connecting to External Products of Integral
7
Flowmeter and Remote Transmitter
7
Wiring Precautions for Power Supply Cables
7
DC Power Connection
8
Grounding
8
Connecting to External Products
8
Wiring Procedures
8
5 Basic Operating Procedures
10
Operation by Display Unit
10
Display and Basic Configuration
10
Display Mode and Setting Mode
10
Parameter Setting from Display Panel
11
Microsd Card Setting
11
BRAIN Configuration Tool
11
HART Configuration Tool
11
Modbus Configuration Tool
11
Foundation
12
Ethernet/Ip Configuration Tool
12
6 Operation
13
Pre-Operation Zero Adjustment
13
Zero Adjustment from Display Unit
13
Hardware Switch Setting
13
Integral Type and AXG4A Remote Transmitter
13
AXG1A Remote Transmitter
14
AXFA11 Remote Transmitter
14
7 Errors and Countermeasures (Display Unit)
15
Advertisement
YOKOGAWA ADMAG TI Series User Manual (12 pages)
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
2
Introduction
3
Safety Instrumented Systems Installation
6
Scope and Purpose
6
Using this Product for an SIS Application
6
Safety Function
6
Safety Accuracy
6
Diagnostic Response Time
6
Setup
7
Required Parameter Setting
7
Proof Test
8
Repair and Replacement
10
Startup Time
10
Firmware Update
10
Reliability Data
10
Lifetime Limits
10
Environmental Limits
10
Application Limits
10
Definitions and Abbreviations
11
Definitions
11
Abbreviations
11
Revision Information
12
YOKOGAWA ADMAG TI Series User Manual (15 pages)
AXG Magnetic Flowmeter, FM (USA) Explosion Protection Type
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
2
Introduction
3
Explosion Protection Type
5
Technical Data
5
Cable Entry
9
Installation
9
Operation
14
Maintenance and Repair
14
Specific Condition of Use
14
Revision Information
15
YOKOGAWA ADMAG TI Series User Manual (7 pages)
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Regarding this User’s Manual
1
Precautions Related to the Protection, Safety, and Alteration of the Product
2
Notes for the Identification Tag
2
For Safe Use of Product
3
Installation, Wiring, and Maintenance
3
Safety Requirements
4
Installation, Wiring, and Maintenance
4
Emc
4
Explosion Protection Type
5
PED (Pressure Equipment Directive)
5
Technical Data
5
Installation
5
Operation
5
Warranty and Disclaimer
6
Revision Information
6
Information on EU WEEE Directive
6
Authorized Representative in EEA
6
Trademarks
6
YOKOGAWA ADMAG TI Series User Manual (12 pages)
Magnetic Flowmeter ATEX Explosion Protection Type
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Introduction
3
2 Explosion Protection Type
5
Technical Data
5
Cable Entry
8
Installation
8
Operation
9
Maintenance and Repair
9
Name Plate
10
Specific Condition of Use
11
Revision Information
12
YOKOGAWA ADMAG TI Series Read Me First (8 pages)
Magnetic Flowmeter
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Regarding this User’s Manual
1
For Safe Use of Product
1
Precautions Related to the Protection, Safety, and Alteration of the Instrument
1
Purpose of Use
2
Power Supply
2
Connect the Protective Grounding Terminal
2
Installation, Wiring, and Maintenance
2
Warning and Disclaimer
3
Installation, Wiring, and Maintenance (Continued)
3
Conform to IEC61010(-1 and -30)-2010
3
Revision Information
4
About Digital User’s Manual
4
Trademarks
4
YOKOGAWA ADMAG TI Series User Manual (14 pages)
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
For Safe Use of Product
4
Safety Requirements
6
Revision Information
6
Explosion Protection Type
6
Warranty and Disclaimer
6
YOKOGAWA ADMAG TI Series User Manual (10 pages)
Magnetic Flowmeter
Brand:
YOKOGAWA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
For Safe Use of Product
3
Safety Requirements
4
Explosion Protection Type
5
Warranty and Disclaimer
5
Revision Information
5
Advertisement
Related Products
YOKOGAWA Admag TI AXG
YOKOGAWA Admag TI AXW
YOKOGAWA ADMAG AXF Series
YOKOGAWA ADMAG AXG Series
YOKOGAWA ADMAG AXG015
YOKOGAWA ADMAG AXR
YOKOGAWA ADMAG AXW Series
YOKOGAWA Admag AXW
YOKOGAWA AXW150
YOKOGAWA AXF***C Series
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL