YOKOGAWA Admag TI Series User Manual page 73

Foundation fieldbus communication type
Hide thumbs Also See for Admag TI Series:
Table of Contents

Advertisement

Block
Relative
Name
Index
STB
109
STB
110
STB
111
STB
112
STB
113
STB
STB
114
STB
115
STB
116
STB
117
Volumetric flow rate limit switch
Display
F
OUNDATION
Fieldbus
Block
Relative
Name
Index
STB
118
STB
STB
119
STB
120
STB
121
STB
122
STB
123
STB
STB
124
STB
125
STB
126
STB
127
Parameter
Display
F
OUNDATION
--
Lmt Sts Velo1 Sp
--
Lmt Sts Velo1 Act Dir
--
Lmt Sts Velo1 Hys
--
Lmt Sts Velo1 Unit
Limit Sts Velocity2 Value ►
--
Lmt Sts Velo2.Status
Limit Sts Velocity2 Value ►
--
Lmt Sts Velo2.Value
--
Lmt Sts Velo2 Sp
--
Lmt Sts Velo2 Act Dir
--
Lmt Sts Velo2 Hys
--
Lmt Sts Velo2 Unit
--
Device Configuration ► STB ► Device Configuration ► Configuration ►Limit Sts Volume
► (see below)
Parameter
Display
F
OUNDATION
Limit Sts Volume1 Value ►
--
Lmt Sts Vol1.Status
Limit Sts Volume1 Value ►
--
Lmt Sts Vol1.Value
--
Lmt Sts Vol1 Sp
--
Lmt Sts Vol1 Act Dir
--
Lmt Sts Vol1 Hys
--
Lmt Sts Vol1 Unit
Limit Sts Volume2 Value ►
--
Lmt Sts Vol2.Status
Limit Sts Volume2 Value ►
--
Lmt Sts Vol2.Value
--
Lmt Sts Vol2 Sp
--
Lmt Sts Vol2 Act Dir
--
Lmt Sts Vol2 Hys
--
Lmt Sts Vol2 Unit
<5. Functions>
Fieldbus
Specifies the threshold of flow velocity
limit switch 1.
Specifies the operation direction of flow
velocity limit switch 1.
Specifies the hysteresis of flow velocity
limit switch 1.
Displays the unit of the flow velocity.
Displays the status of the contact point
output of flow velocity limit switch 2.
Displays the contact point output of flow
velocity limit switch 2.
Specifies the threshold of flow velocity
limit switch 2.
Specifies the operation direction of flow
velocity limit switch 2.
Specifies the hysteresis of flow velocity
limit switch 2.
Displays the unit of the flow velocity.
Fieldbus
Displays the status of the contact point
output of volumetric flow rate limit switch
1.
Displays the contact point output of
volumetric flow rate limit switch 1.
Specifies the threshold of volumetric flow
rate limit switch 1.
Specifies the operation direction of
volumetric flow rate limit switch 1.
Specifies the hysteresis of volumetric flow
rate limit switch 1.
Displays the unit of the volumetric flow
rate.
Displays the status of the contact point
output of volumetric flow rate limit switch
2.
Displays the contact point output of
volumetric flow rate limit switch 2.
Specifies the threshold of volumetric flow
rate limit switch 2.
Specifies the operation direction of
volumetric flow rate limit switch 2.
Specifies the hysteresis of volumetric flow
rate limit switch 2.
Displays the unit of the volumetric flow
rate.
72
Description
Description
IM 01E21A02-03EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admag ti axgAdmag ti axw

Table of Contents