YOKOGAWA Admag TI Series User Manual page 97

Foundation fieldbus communication type
Hide thumbs Also See for Admag TI Series:
Table of Contents

Advertisement

NE
107
Display
C
361:DiagTB O/S Mode
C
362:MaintTB O/SMode
C
363:DispTB O/S Mode
Warning
The device works normally and measurement is also normal but warning occurs.
NE
107
Display
S
082:Pls 1 saturate
C
085:Cable miscon
C
086:Coil insulation
M
087:Adhesion lv 3
N
088:LC warn
M
089:Insu detect
N
090:FLN over lv 3
N
091:FLN over lv 4
C
092:AZ warn
C
093:Verif warn
C
094:Fact noise warn
C
095:Simulate active
S
098:Pls 1 fix
Error Message
F
OUNDATION
Fieldbus
Diagnostic TB in
O/S Mode
Maintenance TB in
O/S Mode
Display TB in O/S
Mode
Error Message
F
OUNDATION
Fieldbus
Pulse output 1
saturated
Cable misconnect
Coil insulation
warning
Adhesion over level
3
Low conductivity
warning
Insulation detection
Flow noise over
level 3
Flow noise over
level 4
Autozero warning
Verification warning
Factory noise
warning
Simulation active
Pulse output 1 fixed
<5. Functions>
Error Description
The DTB block is in the
Change the DTB block
O/S mode.
mode.
The MTB block is in the
Change the MTB block
O/S mode.
mode.
The LTB block is in the
Change the LTB block
O/S mode.
mode.
Error Description
Check process value
Saturation of pulse
and pulse output 1
output 1 was detected.
parameter settings.
Check the signal cable
Misconnection of cable
and excitation cable
was detected.
connection.
Insulation deterioration
Contact Yokogawa
of the coil was
service center.
detected.
The resistance value
of the electrodes
exceeded Level 3.
Recommend cleaning
(Adhesion detection
the electrode.
of insulation to the
electrode)
Decrease of
Check fluid
conductivity was
conductivity.
detected.
Insulation deterioration
Contact Yokogawa
of electrode was
service center.
detected.
Flow noise exceeded
Check if the fluid has a
Level 3.
problem (conductivity
(Detection of flow
and bubble).
noise)
Flow noise exceeded
Check if the fluid has a
Level 4.
problem (conductivity
(Detection of flow
and bubble).
noise)
Result of zero
Check fluid is stopped
adjustment exceeded
when executing zero
10 cm/s.
adjustment.
Interruption of
Execute the Verification
verification function
function again.
was detected.
The fluctuation of flow
Check the fluid.
became larger.
The test mode for any
of the flow velocity,
volumetric flow rate,
Release simulation or
mass flow rate, calorie,
test mode.
pulse output, status
input, or status output
was executed.
Check whether pulse
It was detected that
output 1 is in the test
pulse output 1 is fixed.
mode or not.
Countermeasure
FD bit
7
7
7
Countermeasure
FD bit
3
3
3
4
4
4
4
4
4
4
4
4
4
IM 01E21A02-03EN
96
14
13
12
5
2
1
31
30
29
28
27
26
25
24
23
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Admag ti axgAdmag ti axw

Table of Contents