CUA31/CUA32 control unit adapter

Characteristics of the CUA31/CUA32
You can connect a Power Module in blocksize format to the DRIVE-CLiQ interface using the
CUA31 adapter module. The CUA32 adapter module also provides an encoder interface for
an HTL, TTL or SSI encoder.
Table 8-4
Interface
DRIVE-CLiQ interface
EP terminals/temperature sensor
connection
Power Module Interface (PM-IF)
24 V electronic power supply
Encoder interface (HTL, TTL, SSI)
Only SSI encoders without incremental
tracks may be operated.
Maximum DRIVE-CLiQ cable length
NOTICE
Overheating if ventilation clearances are too small
Insufficient ventilation clearances result in overheating and therefore in more failures and a
shortened life of the component.
The 50 mm clearances above and below the components must be observed. The ventilation
openings may not be covered by connecting cables.
Additional references
You will find more information on the CUA31/CUA32 control unit adapter in the
SINAMICS S120 AC Drive Manual.
SIMOTION D410
Manual, 04/2014
Overview of the interfaces for the adapter modules
8.5 CUA31/CUA32 control unit adapter
CUA31
3
1
1
1
0
with order number
6SL3040-0PA00-0AA0
→ 50 m
as of order number
6SL3040‑0PA00‑0AA1
→ 100 m
Spare parts/Accessories
CUA32 (V4.1 SP2 and
higher)
3
1
1
1
1
100 m