7.5.2

Using vector drives

Changes need to be made in HW Config when using SINAMICS vector drives. This means,
for example, that the T
drives or, with chassis drives, also on the device type used.
Therefore, we recommend adopting the following procedure when using vector drives with the
SIMOTION D4x5‑2.
Scenario 1: Current and speed controller cycle is known
As long as you know the current and speed controller cycle, you will be able to determine times
T
MAPC
cycle clock must be used for the current and speed controller cycle.
Procedure
1. Open HW Config. By "double clicking" the SINAMICS Integrated, you can change the
properties of the DP slave in the "Isochronous operation" tab.
2. For T
3. For T
Integrated, T
4. Enter T
cycle clock > DP cycle).
5. Use the "Download project to target system" menu command to load the configuration to
the SIMOTION D4x5‑2.
6. After the download has successfully completed, you should determine the current and
speed controller cycles of the drives from the drives' expert lists, as the cycle clocks are
set in the SINAMICS drive unit after a project has been downloaded.
p0115[0] current controller cycle clock
p0115[1] speed controller cycle clock
7. If the current and speed controller cycles from the expert lists are different to the cycle
clocks used in steps 2 and 3, you will have to repeat the steps with the current values for
the current and speed controller cycles.
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B
7.5 Additional information on configuring the SINAMICS Integrated
/T
time and the minimum DP cycle depend on the number of vector
I
O
, T
, T
, and T
. Where there are several drives with different cycle clocks, the largest
DP
I
O
= T
=, enter an integer multiple of the current controller cycle.
I
O
, enter an integer multiple of the speed controller cycle. For drives on the SINAMICS
DP
must always be ≥ T
DP
= T
(exception: you are working with cycle clock scaling; i.e. position control
MAPC
DP
.
O
Commissioning (software)
227