5.3.1
General notes on parameters
Each parameter features a 16-bit index as address. Under this address, the parameter is
stored in the object directory of the inverter.
Parameters that belong together functionally are combined in a data set. These parame-
•
ters are additionally provided with an 8-bit subindex.
The colon is used as a separator between the index and subindex Example: "0x2540:001"
•
There are parameters the setting of which can be changed, and (diagnostic) parameters
•
which can only be read.
Parameterisation using the keypad
All parameters which can be accessed by means of the keypad are provided with a "Display
•
code", the first digit of the display code specifying the group in which the parameter can
be found on the keypad.
In the documentation, the display code — if available — is specified in brackets behind the
•
address. Example: "0x2915 (P210.00)".
4Keypad parameterisation mode
Structure of the parameter descriptions in this documentation
The parameter descriptions in this documentation are structured in table form.
•
The representation distinguishes parameters with a setting range, text, selection list, and
•
bit-coded display.
The default setting of parameters with a write access feature is shown in bold.
•
The display code as well as the short keypad designation of the parameter which is limited
•
to 16 characters, are — if available — shown in brackets.
Example: parameters with a setting range
Parameter
Name / value range / [default setting]
Index:Subindex
Parameter designation
(display code)
(abbreviated keypad designation)
Minimum value ... [default setting] ... maximum value
• Optional information with regard to the parameter.
Example: parameters with a selection list
Parameter
Name / value range / [default setting]
Index:Subindex
Parameter designation
(display code)
(abbreviated keypad designation)
• Optional information with regard to the parameter.
0 Designation of selection 0
1 Designation of selection 1
2 Designation of selection 2
Example: parameters with a bit-coded display
Parameter
Name / value range / [default setting]
Index:Subindex
Parameter designation
(display code)
(abbreviated keypad designation)
• Optional information with regard to the parameter.
Bit 0 Designation of bit 0
Bit 1 Designation of bit 1
Bit 2 Designation of bit 2
... ...
Bit 15 Designation of bit 15
Parameter overview lists in this documentation
Keypad parameter
list: for the parameterisation using the keypad, contains a list of all
•
parameters which can also be accessed by means of the keypad.
Parameter attribute
list: contains a list of all inverter parameters. This list in particular
•
includes some information that is relevant for the reading and writing of parameters via
the network.
^ 659
^ 635
Info
Explanations & notes with regard to the parameter.
Info
Explanations & notes with regard to the parameter.
Note: The corresponding selection number (here 0, 1, or 2) must be set.
Other values are not permissible.
Optionally: Explanations & notes with regard to the corresponding selec-
tion.
The default selection is shown in bold.
Info
Explanations & notes with regard to the parameter.
Optionally: Explanations & notes with regard to the corresponding bit.
Commissioning
General notes on parameters
^ 85
Parameter setting
77