Flexible I/O configuration

Activating ramp 2 manually

14.7
Activating ramp 2 manually
The "Activate ramp 2" function serves to manually activate acceleration time 2 and decelera-
tion time 2.
Parameter
Name / value range / [default setting]
0x2631:039
Function list: Activate ramp 2
(P400.39)
(Function list: Activ. ramp 2)
• For further possible settings, see parameter
0x2631:001
0 Not connected
0x2917
Acceleration time 1
(P220.00)
(Accelerat.time 1)
0.0 ... [5.0] ... 3600.0 s
0x2918
Deceleration time 1
(P221.00)
(Decelerat.time 1)
0.0 ... [5.0] ... 3600.0 s
0x2919
Acceleration time 2
(P222.00)
(Accelerat.time 2)
0.0 ... [5.0] ... 3600.0 s
0x291A
Deceleration time 2
(P223.00)
(Decelerat.time 2)
0.0 ... [5.0] ... 3600.0 s
576
(P400.01).
^ 532
Info
Assignment of a trigger for the "Activate ramp 2" function.
Trigger = TRUE: activate acceleration time 2 and deceleration time 2
manually.
Trigger = FALSE: no action / deactivate function again.
Notes:
• If the function is used and the assigned trigger = TRUE, the auto
change-over threshold
0x291B (P224.00)
• Acceleration time 2 can be set in
• Deceleration time 2 can be set in
Acceleration time 1 for the operating mode "MS: Velocity mode".
• The acceleration time set refers to the acceleration from standstill to
the maximum frequency set. In the case of a lower setpoint selection,
the actual acceleration time is reduced accordingly.
• Setting is not effective in the operating mode
"CiA: Velocity mode [2]".
4Device profile CiA 402
Deceleration time 1 for the operating mode "MS: Velocity mode".
• The deceleration time set refers to the deceleration from the maxi-
mum frequency set to standstill. In the case of a lower actual fre-
quency, the actual deceleration time is reduced accordingly.
• Setting is not effective in the operating mode
"CiA: Velocity mode [2]".
4Device profile CiA 402
Acceleration time 2 for the operating mode "MS: Velocity mode".
• The acceleration time set refers to the acceleration from standstill to
the maximum frequency set. In the case of a lower setpoint selection,
the actual acceleration time is reduced accordingly.
• The acceleration time 2 is active if the frequency setpoint (absolute
value) ≥ auto switching threshold
assigned to the function "Activate ramp 2" in
TRUE.
• The acceleration time 2 is also used for changing the MOP setpoint
generated by the "motor potentiometer" function.
• Setting is not effective in the operating mode
"CiA: Velocity mode [2]".
4Device profile CiA 402
Deceleration time 2 for the operating mode "MS: Velocity mode".
• The deceleration time set refers to the deceleration from the maxi-
mum frequency set to standstill. In the case of a lower actual fre-
quency, the actual deceleration time is reduced accordingly.
• The deceleration time 2 is active if the frequency setpoint (absolute
value) ≥ auto change-over threshold
assigned to the function "Activate ramp 2" in
TRUE.
• The deceleration time 2 is also used for changing the MOP setpoint
generated by the "motor potentiometer" function.
• Setting is not effective in the operating mode
"CiA: Velocity mode [2]".
4Device profile CiA 402
for ramp 2 is deactivated.
0x2919
(P222.00).
0x291A
(P223.00).
0x6060 (P301.00)
=
^ 469
0x6060 (P301.00)
=
^ 469
0x291B (P224.00)
or the trigger
0x2631:039 (P400.39)
0x6060 (P301.00)
=
^ 469
0x291B (P224.00)
or the trigger
0x2631:039 (P400.39)
0x6060 (P301.00)
=
^ 469
=
=

Hide quick links: