Example 2: Start Forward/Start Reverse/Stop (Edge-Controlled) - Lenze i55AE125B Manual

Cabinet 0.25 ... 90 kw
Table of Contents

Advertisement

Flexible I/O configuration
Start / stop motor

Example 2: Start forward/start reverse/stop (edge-controlled)

14.2.2
Example 2: Start forward/start reverse/stop (edge-controlled)
The "Run" function automatically becomes a "start enable" if the functions
"Start forward (CW)"/ "Start reverse (CCW)" are connected to triggers.
This example shows an edge-controlled start/stop via three buttons:
In the non-operating state of button S1 (normally-closed contact), there is already a start
enable.
Button S2 starts the motor in forward rotating direction.
Button S3 starts the motor in backward rotating direction.
Button S1 (normally-closed contact) stops the motor by (short-time) cancellation of the
start command.The inverter then waits for the next start command via button S2/S3.
Connection plan
X3
0 ... 10 V
R1
Parameter
0x2631:001 (P400.01)
0x2631:002 (P400.02)
0x2631:004 (P400.04)
0x2631:006 (P400.06)
0x2631:007 (P400.07)
0x2631:013 (P400.13)
538
S1 S2 S3
Name
Enable inverter
Run
Reset fault
Start forward (CW)
Start reverse (CCW)
Reverse rotational direction
function
Potentiometer R1 Frequency setpoint selection
Button S1 Stopping
Button S2 Start forward (CW)
Button S3 Start reverse (CCW)
Setting for this example
Constant TRUE [1]
Digital input 1 [11]
Not connected [0]
Digital input 2 [12]
Digital input 3 [13]
Not connected [0]