14.9.1

Example 1: Activation via command (only when disabled)

Activation method
0x4046 (P755.00)
Switches S3 and S4 serve to select the parameter set (see the following table).
Switch S2 activates the change-over. Since the change-over is activated with a rising edge,
a button (normally-open contact) can be used instead of a switch.
Change-over is only possible if the motor is not started (switch S1 open).
Connection plan
X3
Parameter
0x2631:001 (P400.01)
0x2631:002 (P400.02)
0x2631:004 (P400.04)
0x2631:013 (P400.13)
0x2631:018 (P400.18)
0x2631:040 (P400.40)
0x2631:041 (P400.41)
0x2631:042 (P400.42)
0x2824 (P200.00)
0x4046 (P755.00)
Input signals
Mains voltage
Trigger
Function
Constant TRUE [1]
Enable inverter
Digital input 1 [11]
Run
Digital input 2 [12]
Load parameter set
Digital input 3 [13]
Select par. set (bit 0)
Digital input 4 [14]
Select par. set (bit 1)
Active parameter set
Output signals
Status signals
Parameter set 1 active [108]
Parameter set 2 active [109]
Parameter set 3 active [110]
Parameter set 4 active [111]
The status signals can be assigned to digital outputs.
The change-over is activated with the "Load parameter set" function (FALSE/TRUE edge).
If the inverter is enabled and the motor is started, a change-over is not possible.
= "Via command (disable required) [0]":
S1 S2 S3 S4
Name
Enable inverter
Run
Reset fault
Reverse rotational direction
Activate preset (bit 0)
Load parameter set
Select parameter set (bit 0)
Select parameter set (bit 1)
Control selection
Activation of parameter set
1
4Configuration of digital outputs
Flexible I/O configuration
Functions for parameter change-over
Example 1: Activation via command (only when disabled)
function
Switch S1 Run
Switch S2 Load parameter set
Switches S3 ... S4 Parameter set selection:
S3
Off
On
Off
On
Setting for this example
Constant TRUE [1]
Digital input 1 [11]
Not connected [0]
Not connected [0]
Not connected [0]
Digital input 2 [12]
Digital input 3 [13]
Digital input 4 [14]
Flexible I/O configuration [0]
Via command (disable required) [0]
2
3
^ 603
S4
Off
Parameter set 1
Off
Parameter set 2
On
Parameter set 3
On
Parameter set 4
4
3
581
t
t
t
t
t
t
t
t
t
t
t