14.15.5.2 Example 2: Pulse train 2 ... 10 kHz ≡ output frequency 30 ... 60 Hz
In this configuration, the output range 2 ... 10 kHz is used for the output of the output fre-
quency (resolution: 0.1 Hz). The example shows how the signals outside the signal range
(here: 30 ... 60 Hz) are cut off.
Parameter
0x2644:001 (P423.01)
0x2644:002 (P423.02)
0x2644:003 (P423.03)
0x2644:004 (P423.04)
0x2644:005 (P423.05)
Output frequency [1]
616
Designation
DO1 frequency setup: Minimum frequency
DO1 frequency setup: Maximum frequency
DO1 frequency setup: Function
DO1 frequency setup: Minimum signal
DO1 frequency setup: Maximum signal
0x2644:003
Pulse train [kHz]
10
2
0
0
Setting for this example
2000.0 Hz
10000.0 Hz
Output frequency [1]
300
600
X3
Max
DO1
Hz
Min
300
600
30.0
60.0
[0.1 Hz]