Diagnostics parameter

The inverter provides many diagnostic parameters which are helpful for operation, mainte-
nance, error diagnosis, error correction, etc.
In the following overview the most common diagnostic parameters are listed. For the key-
pad you can find these diagnostic parameters in group 1.
Further parameters for more specific diagnostic purposes are described in the following
subchapters.
The diagnostic parameters can only be read and cannot be written to.
Parameter
Name / value range / [default setting]
0x2030
CRC parameter set
• Read only
0x2B0B
Frequency setpoint
• Read only: x.x Hz
• From version 03.00
0x2B0E
Frequency setpoint
(P102.00)
(Freq. setpoint)
• Read only: x.x Hz
0x2B0F
VFC output frequency
• Read only: x.x Hz
0x2D4F
Motor utilisation (i²*t)
(P123.00)
(Mot. i2t utilis.)
• Read only: x %
0x2D87
DC-bus voltage
(P105.00)
(DC-bus voltage)
• Read only: x V
0x2D88
Motor current
(P104.00)
(Motor current)
• Read only: x.x A
0x2D89
Motor voltage
(P106.00)
(Motor voltage)
• Read only: x VAC
0x2DA2:001
Output power: Effective power
(P108.01)
(Output power: Effective power)
• Read only: x.xxx kW
0x2DA2:002
Output power: Apparent power
(P108.02)
(Output power: Apparent power)
• Read only: x.xxx kVA
0x2DA3:001
Output energy: Motor
(P109.01)
(Output energy: Motor)
• Read only: x.xx kWh
0x2DA3:002
Output energy: Generator
(P109.02)
(Output energy: Generator)
• Read only: x.xx kWh
0x2DDD
Output frequency
(P100.00)
(Output frequency)
• Read only: x.x Hz
0x400D
Scaled actual value
(P101.00)
(Scaled act value)
• Read only: x Units
0x6077
Torque actual value
(P107.00)
(Torque actual)
• Read only: x.x %
0x6078
Current actual value
(P103.00)
(Current actual)
• Read only: x.x %
Diagnostics and fault elimination
Info
Display of the 32-bit hash sum for the integrity check of the parameter
set.
Display of the actual frequency setpoint that is internally transferred to
the motor control (after scaling and ramp generator).
Display of the frequency setpoint currently assigned.
• Depending on the present operating conditions, this value may differ
from the current output frequency
Display of the current output frequency at V/f operation.
Display of the current thermal motor utilisation.
Display of the current DC-bus voltage.
Display des present current-r.m.s. value.
Display of the current motor voltage.
Display of the active output power for an energy analysis in the respec-
tive application.
Display of the apparent output power for an energy analysis in the
respective application.
Display of the output power in motor mode for an energy analysis in the
respective application.
Display of the output power in generator mode for an energy analysis in
the respective application.
Display of the current output frequency for diagnostics of the control.
Display of the current speed in application units.
Display of the current torque.
• 100 % ≡ Motor rated torque
0x6076 (P325.00)
Display of the present motor current.
• 100 % ≡ Motor rated current
0x6075 (P323.00)
Diagnostics parameter
0x2DDD
(P100.00).