Additional functions

Access protection

Write access protection

11.7
Access protection
11.7.1
Write access protection
Optionally a write access protection can be installed for the inverter parameters.
Write access protection only restricts parameterisation via keypad and »EASY
Starter«. Write access protection via network is not restricted. Irrespective of
the write access protection that is currently set, a higher-level controller, OPC-
UA server, or any other communication partner connected to the inverter is
always provided with full read/write access to all parameters of the inverter.
After activating the write access protection, you have to enter a valid PIN to
remove the write access protection. Note down the defined PIN(s) and keep this
information in a safe place! If you lose the PIN(s), the inverter can only be disa-
bled by resetting it to the delivery status. This means, all parameter settings
made by the user get lost!
Details
Usually the write access protection function is implemented by the mechanical engineer/
OEM , for example to protect the inverter against incorrect parameterisation by non-author-
ised persons. For diagnostic purposes, a read access to all parameters is always possible.
The write access protection allows for the following configurations:
Full write access
Write access only to favorites or (when knowing PIN1) to all parameters
No write access or (when knowing PIN2) full write access
No write access or (when knowing PIN1) write access only to favorites or (when knowing
PIN2) to all parameters
The following table compares the four possible configurations:
PIN1 setting
PIN2 setting
0x203D (P730.00)
0x203E (P731.00)
0
0
> 0
0
0
> 0
> 0
> 0
450
4Reset parameters to default
Log-in
Status display after
log-in
0x203F
0x2040 (P197.00)
-
0
Access
Diagnostics (read access)
0 or wrong PIN
2
Correct PIN1
0
Access
Diagnostics (read access)
0 or wrong PIN
1
Correct PIN2
0
Access
PIN2
Diagnostics (read access)
0 or wrong PIN
1
Correct PIN1
2
Correct PIN2
0
Access
PIN1
Diagnostics (read access)
If PIN1 and PIN2 are set identically, a write access to all parameters is possible after the PIN has been
entered correctly.
^ 418
Active write access protection (via keypad/»EASY Starter«)
No access protection configured.
Favorites
Write access only possible to favorites.
Write access to all parameters possible.
PIN1
Favorites
No write access.
Write access to all parameters possible.
Favorites
No write access.
Write access only possible to favorites.
Write access to all parameters possible.
PIN2
Favorites
All parameters
All parameters
All parameters
All parameters