9.9.6

Data mapping

The process data are used to control the inverter.
The process data is transmitted cyclically between the IO-Controller and the IO-Devices partic-
ipating at the PROFINET:
The available 27 network registers ("slots") serve to maximally exchange 16 process data
words (data types 8-bit or 16-bit) or 8 process data double words (data type 32-bit) for
each direction.
Output data direction: From IO-Controller to IO-Device.
Input data direction: From IO-Device to IO-Controller.
Data mapping is used to define which process data are exchanged cyclically between IO-Con-
troller andIO-Device.
Details
If the inverter is known in the PROFINET network as node and the IO-Controller connects
to the IO-Device for the first time, the mapping objects are automatically transferred to
the IO device, i. e. to the inverter.
Internal mapping of the process output data is set in
Internal mapping of the process input data is set in
All subsequent changes in the objects 0x24E1 and 0x24E1 can cause PROFINET
alarms according to the deviation of the automatically set configurations.
Configuring the network
0x24E0:001
... 0x24E0:016.
0x24E1:001
... 0x24E1:016.
PROFINET
Data mapping