Configuring the network
PROFINET
Monitoring
9.9.5
Monitoring
The parameters for setting network monitoring functions are described below.
Parameter
Name / value range / [default setting]
0x2859:001
PROFINET monitoring: Watchdog elapsed
(P515.01)
(PROFINET monit.: WD elapsed)
• From version 02.00
• For further possible settings, see parameter
0x2D45:001
2 Trouble
0x2859:002
PROFINET monitoring: Data exchange exited
(P515.02)
(PROFINET monit.: Data exch.exited)
• For further possible settings, see parameter
0x2D45:001
0 No response
0x2859:003
PROFINET monitoring: Invalid configuration
(P515.03)
(PROFINET monit.: Invalid config)
• From version 02.00
• For further possible settings, see parameter
0x2D45:001
2 Trouble
0x2859:004
PROFINET monitoring: Initialisation error
(P515.04)
(PROFINET monit.: Init. error)
• From version 02.00
• For further possible settings, see parameter
0x2D45:001
2 Trouble
0x2859:005
PROFINET monitoring: Invalid process data
(P515.05)
(PROFINET monit.: Inval. proc.data)
• From version 02.00
• For further possible settings, see parameter
0x2D45:001
2 Trouble
370
(P310.01).
^ 223
(P310.01).
^ 223
(P310.01).
^ 223
(P310.01).
^ 223
(P310.01).
^ 223
Info
Selection of the response to a permanent interruption of the communi-
cation to the IO controller.
Associated error code:
33168
|
0x8190
- Network: watchdog timeout
•
Selection of the response triggered by the reception of invalid configura-
tion data.
Associated error code:
33414
|
0x8286
- Network: PDO mapping error
•
Selection of the response triggered by the occurrence of an error during
the initialisation of the network component.
Associated error code:
33170
|
0x8192
- Network: initialisation error
•
Selection of the response triggered by the reception of invalid process
data.
Process data marked as invalid (IOPS is "BAD") are received by the IO
Controller. Typically in case of
• a PLC in STOP state,
• alarms,
• acyclic demand data.
Associated error code:
33171
|
0x8193
- Network: invalid cyclic process data
•