Example 1: Automatic Dc Braking When The Motor Is Started - Lenze i55AE125B Manual

Cabinet 0.25 ... 90 kw
Table of Contents

Advertisement

11.4.1

Example 1: Automatic DC braking when the motor is started

In order that the DC braking is automatically active when the motor is started, the start
method "DC braking [1]" must be set in
The DC braking is carried out with the braking current set in
Only after the hold time
the setpoint.
Parameter
0x2631:001 (P400.01)
0x2631:002 (P400.02)
0x2631:004 (P400.04)
0x2838:001 (P203.01)
0x2860:001 (P201.01)
0x2911:001 (P450.01)
0x2B84:001 (P704.01)
0x2B84:002 (P704.02)
Input signals
Frequency setpoint selection
Trigger
Function
Digital input 1 [11]
Enable inverter
Digital input 2 [12]
Run
Output signals
Output frequency
0x2DDD
Status signals
Running [50]
Stop active [53]
DC braking active [67]
The status signals can be assigned to digital outputs.
After the start command, the DC braking is active. Only after the hold time
the setpoint.
The motor is stopped with the stop method set in
If the inverter is disabled, the motor coasts.
0x2838:001
(P203.01).
0x2B84:002 (P704.02)
has elapsed, the motor is accelerated to
Name
Enable inverter
Run
Reset fault
Start method
Frequency control: Default setpoint source
Frequency setpoint presets: Preset 1
Current
Automatic hold time
60 Hz
50 Hz
40 Hz
30 Hz
20 Hz
10 Hz
0 Hz
60 Hz
50 Hz
40 Hz
30 Hz
20 Hz
10 Hz
0 Hz
4Configuration of digital outputs
0x2838:003
Example 1: Automatic DC braking when the motor is started
0x2B84:001
(P704.01).
Setting for this example
Digital input 1 [11]
Digital input 2 [12]
Not connected [0]
DC braking [1]
Frequency preset 1 [11]
40 Hz
50 %
10 s
^ 603
0x2B84:002 (P704.02)
(P203.03). In the example: Stop with standard ramp.
Additional functions
DC braking
has elapsed, the motor is accelerated to
t
t
t
t
t
t
t
439