8.4.3
Motor equivalent circuit diagram data
The motor equivalent circuit diagram data are automatically set if one of the following optimi-
sations is carried out:
4Motor selection from motor catalogue
4Automatic motor identification (energized)
4Automatic motor calibration (non-energized)
Parameter
Name / value range / [default setting]
0x2C01:002
Motor parameters: Stator resistance
0.0000 ... [10.1565]* ... 125.0000 Ω
* Default setting depending on the size.
0x2C01:003
Motor parameters: Stator leakage inductance
0.000 ... [23.566]* ... 500.000 mH
* Default setting depending on the size.
0x2C02:001
Motor parameter (ASM): Rotor resistance
(P351.01)
(ASM motor par.: Rotor resistance)
0.0000 ... [8.8944]* ... 200.0000 Ω
* Default setting depending on the size.
0x2C02:002
Motor parameter (ASM): Mutual inductance
(P351.02)
(ASM motor par.: Mutual induct.)
0.0 ... [381.9]* ... 50000.0 mH
* Default setting depending on the size.
0x2C02:003
Motor parameter (ASM): Magnetising current
(P351.03)
(ASM motor par.: Magn. current)
0.00 ... [0.96]* ... 500.00 A
* Default setting depending on the size.
^ 197
^ 199
^ 200
Info
General motor data.
Carry out settings as specified by manufacturer data/motor data sheet.
Equivalent circuit data of the motor required for the motor model.
Motor control
Optimisation of the control loops
Motor equivalent circuit diagram data