14.9.3

Example 3: Activation if the selection is changed (only if the inverter is disabled)

Activation method
0x4046 (P755.00)
Switches S3 and S4 serve to select the parameter set (see the following table). At the same
time, the change-over is activated by a status change of the selection inputs.
Change-over is only possible if the motor is not started (switch S1 open).
Switch S2 ("Load parameter set") is ignored in this configuration.
Connection plan
X3
Parameter
0x2631:001 (P400.01)
0x2631:002 (P400.02)
0x2631:004 (P400.04)
0x2631:013 (P400.13)
0x2631:018 (P400.18)
0x2631:040 (P400.40)
0x2631:041 (P400.41)
0x2631:042 (P400.42)
0x2824 (P200.00)
0x4046 (P755.00)
Input signals
Mains voltage
Trigger
Function
Constant TRUE [1]
Enable inverter
Digital input 1 [11]
Run
Digital input 2 [12]
Load parameter set
Digital input 3 [13]
Select par. set (bit 0)
Digital input 4 [14]
Select par. set (bit 1)
Active parameter set
Output signals
Status signals
Parameter set 1 active [108]
Parameter set 2 active [109]
Parameter set 3 active [110]
Parameter set 4 active [111]
The status signals can be assigned to digital outputs.
The "Load parameter set" function is ignored in this configuration.
Change-over takes place by a status change of the selection inputs.
If the inverter is enabled and the motor is started, a change-over is not possible.
Example 3: Activation if the selection is changed (only if the inverter is disabled)
= "If the selection is changed (disable required) [2]":
S1 S2 S3 S4
Name
Enable inverter
Run
Reset fault
Reverse rotational direction
Activate preset (bit 0)
Load parameter set
Select parameter set (bit 0)
Select parameter set (bit 1)
Control selection
Activation of parameter set
1
2
4Configuration of digital outputs
Flexible I/O configuration
Functions for parameter change-over
function
Switch S1 Run
Switch S2 Load parameter set (is ignored in this configura-
tion)
Switches S3 ... S4 Parameter set selection and activation at the
same time:
S3
Off
On
Off
On
Setting for this example
Constant TRUE [1]
Digital input 1 [11]
Not connected [0]
Not connected [0]
Not connected [0]
Digital input 2 [12]
Digital input 3 [13]
Digital input 4 [14]
Flexible I/O configuration [0]
If the selection is changed (disable required) [2]
1
4
^ 603
S4
Off
Parameter set 1
Off
Parameter set 2
On
Parameter set 3
On
Parameter set 4
3
3
583