Parameter
Name / value range / [default setting]
0x2860:003
Torque control: Default setpoint source
(P201.03)
(Stnd. setpoints: Torque setp.src.)
• From version 03.00
1 Keypad
2 Analog input 1
3 Analog input 2
4 HTL input
5 Network
11 Torque preset 1
12 Torque preset 2
13 Torque preset 3
14 Torque preset 4
15 Torque preset 5
16 Torque preset 6
17 Torque preset 7
18 Torque preset 8
31 Segment preset 1
32 Segment preset 2
33 Segment preset 3
34 Segment preset 4
35 Segment preset 5
36 Segment preset 6
37 Segment preset 7
38 Segment preset 8
50 Motor potentiometer
201 Internal value
202 Internal value
203 Internal value
204 Internal value
205 Internal value
206 Internal value
7.4.1

Keypad setpoint default setting

For the manual setpoint selection via keypad the following default settings are used.
Parameter
Name / value range / [default setting]
0x2601:001
Keypad setpoints: Frequency setpoint
(P202.01)
(Keypad setpoints: KP freq.setpoint)
0.0 ... [20.0] ... 599.0 Hz
0x2601:002
Keypad setpoints: Process controller setpoint
(P202.02)
(Keypad setpoints: KP PID setpoint)
-300.00 ... [0.00] ... 300.00 PID unit
(from version 04.00)
(from version 05.00)
(from version 05.00)
(from version 05.00)
(from version 05.00)
(from version 05.00)
(from version 05.00)
Info
Selection of the standard setpoint source for operating mode "MS: Tor-
que mode".
• The selected standard setpoint source is always active in the operat-
ing mode
0x6060 (P301.00)
= "MS: Torque mode [-1]" when no set-
point change-over to another setpoint source via corresponding trig-
gers/functions is active.
The setpoint is specified locally by the keypad.
• Default setting:
0x2601:003 (P202.03)
• Use the
and
navigation keys to change the keypad setpoint
(also during running operation).
The setpoint is defined as analog signal via the analog input 1.
4Analog input 1
^ 597
The setpoint is defined as analog signal via the analog input 2.
4Analog input 2
^ 601
The digital inputs DI3 and DI4 can be configured as HTL input to use an
HTL encoder as setpoint encoder or define the setpoint as a reference
frequency ("pulse train").
4HTL input setpoint source
^ 565
The setpoint is defined as process data object via the network.
4Configuring the network
^ 226
For the setpoint selection, preset values can be parameterised and selec-
ted.
4Setpoint source of preset setpoints
For the setpoint selection, the segment presets parameterised for the
"sequencer" function can be selected as well.
4Sequencer
^ 504
The setpoint is generated by the "motor potentiometer" function. This
function can be used as an alternative setpoint control which is control-
led via two signals: "MOP setpoint up" and "MOP setpoint down".
4Motor potentiometer setpoint source (MOP)
Internal values of the manufacturer.
Info
Default setting of the keypad setpoint for the operating mode
(P301.00)
= "MS: Velocity mode [-2]".
Default setting of the keypad setpoint for the reference value of the PID
control.
Basic setting
Selection of setpoint source
Keypad setpoint default setting
^ 554
^ 559
0x6060
151