DESCRIPTION
:user Run Temperature
lisplay. This code switches
.he fuser heat rod on and
ncreases the fuser heat roll
emperature to the run
emperature. The run
emperature is displayed in
iegrees (F) and degrees (C).
4 t
run temperature, the
)rum/ Developer and Fuser
)rive Motors are switched on.
rhe following conditions may
?xist
when the message,
USER
CAN NOT BE TURNED
3N, CONDITION XX is
jisplayed:
03 Developer Cover
i s
open
04 Cutter Cover i s open
05 Xerographic interlock
is
open
06 Right side door i s
open
07
Document Handler
interlock is open
08
Fuser status problem,
Turn power off and
try again
09 Illumination status
problem, Turn ower
P
off and try aga n
:user Scorch Sensor
:Thermistor RT2).
iignal i s 1 with Fuser
temperature
=
<
4200
F
:2150C). Signal is
0
with Fuser
temperature
=
>
4200 F
: 2 l S 0 C).
Note: Power must
se switched off then on, in
wder to reset signal.
-
CODE
-
1026
-
1060
-
1061
-
1062
-
1063
-
9903
-
DESCRIPTION
- -
Resets the f user control NVM
to default values.
Fuser Temperature Adjust
This code allows the
adjustment of the fuser run
temperature. Run
temperature
is
3200 F (1 600 C )
with 36 inch wide bond
media.
Refer to AD1 10.1 Fuser
Temperature
This code adjusts the
temperature at which the
main drive starts turnina.
This code adjusts the
temperature offset between
bond and vellum.
This code adjusts the
temperature offset between
bond and film.
This code initializes all the
stepper motor values to
default values.
Image on Drum (Panic Stop)
Procedure
This procedure allows the isolation of copy
quality problems by observing the image on
the drum before the transfer of the toner to
the media. If the defect is visible on the
drum before the transfer, the defect is
related to the charge, the imaging, or the
developer.
If
the defect
is
visible on the copy
after the transfer, the defect i s related to the
transfer or fuser.
Make a copy of Test Pattern,
82E5980;
open the right door interlock when the
test pattern i s almost half way into the
document handler.
Remove the Developer Module.
If
the defect
is
visible on the developed
image, the defect cause
is
related to the
charge, the imaging, or the developer. If
the defect is not visible, the defect cause
i s related to the transfer or the fuser.