CQ 9 Length Distortion
Probable Cause
Corrective Action
1. There is contamination or static on the
1. Clean the platen with Antistatic Cleaner.
platen.
2. Document speed
is too fast or too slow.
2.
Perform the Copy Size Adjustment (ADJ
5.1).
3. Media is damp.
3a. Cut sheet media:
Make a copy, using a sheet of media from
a new pack of media.
If the problem is corrected, ensure that the
roll media
is
being stored correctly.
3b. Roll media:
Remove and discard the first 3 to 6 feet (1
to 2 metres) of media from the roll. Make
a copy on the new media.
If the problem is corrected, ensure that the
roll media
is
being stored correctly.
Refer to section
2
and ensure that the
media heater is working.
Definition
4. Media speed at the fuser is incorrect.
4. There i s too much or too little oil on the
Length distortion, often referred to as copy
Media is moving too slowly.
fuser roll. Check the oil dispense wick for
enlargement or reduction, can be any of the
contamination and sufficient oil. Clean
following:
1
the Oil Dispense Roll with Film Remover.
a. The image on the media is longer
5.
The lower document feed rolls are
5. Goto theCQ 17Skewed Image RAP.
than the image on the document.
contaminated.
b. The image on the media
is shorter
6. Worn fabricguide
than the image on the document.
.
c. One side of the media image i s larger
than the other side
6. Replace Fabric Guide (REP 8.9)