Adjust
1. (Figure 3): Adjust the Toner Home Sensor.
0
STEPS 1 Cand D: The toner home sensor
2. Reconnect the sensor and secure the wires.
is threaded. The wires need to be
straightened to rotate the sensor for
adjustment.
C
STRAIGHTEN THE WIRES
D
E
MEASURE 3i32
INCH
f
1/64(2.5
mm
+-
0.5mm)
SENSOR
DISCONNECT
REMOVE THE WIRES
FROM THE FASTENERS (2
PLACES)
Figure 3. Adjust the Toner Home Sensor
(Continued)
ADJ 9.5