7.2
Roll 2 Feed
RAP
(9123192)
This RAP
is
used for Roll 2 feed problems that
may or may not indicate a status code.
The problem may occur if there is a problem
with
the
Roll
2
drive
mechanical
components, the Roll Drive Motor or the
motor control circuitry.
NOTE:
The component locator drawings and
the circuit diagram are on the next five
pages.
Initial Actions
Check that the media is in good
condition and i s loaded correctly.
Check the Upper Feed Baffle that
houses the Feed Pinch Rolls i s latched
in the correct position.
Check
the
media
path
for
obstructions.
Check the Roll Drive Motor, drive
chain and sprockets for binding by
rotating the Feed Drive Sprocket
manually. The sprocket will drive the
Media Drive Chain, which will rotate
the motor and sprockets.
Pull out the Drawer
2.
Check the Feed
Drive Rolls, Feed Pinch Rolls, and Roll
Load Springs for contamination or
damage and correct installation.
Clean or replace a s required.
Check the Rewind Gears, Roll Arbors,
and Arbor Support Rolls for binding or
damage.
Check the connectors for the Roll
Drive Motor (A7 PZ),
Drive Motor
PWB (A7 PI) and Control PWB (A3
P308) for damage. Ensure that the
connectors are seated correctly.
Ensure that the customer
is
running
media
that
meet
the
type
specification.
Ensure that the customer is running
media that meet the size specification.
With the copier in the Power Saver
Mode, check that the media heater is
warm. Refer to the OF1 Media Heater
RAP a s required.
Procedure
NOTE:
In order to prevent a media jam,
ensure to remove the media from the Feed
Drive and Pinch Rolls,
Remove the Roll
2
Media from the Feed
Drive and Pinch Rolls. 'Cheat the Front Covers
Interlocks. Enter the code [0717-BOND] in
order to check the Roll Drive Motor and Roll
2 Feed Clutch.
The Roll 2 Feed Drive Roll rotates.
Y
N
The Roll Drive Motor is energized.
Go to
FLAG 1
and check for an open
circuit in the wires to the Drive
Motor
PWB.
If the check i s good, press the Power
Off (0) switch. Disconnect the drive
motor connector (A7 P2).
Set the
Multimeter (600T1616) to ohms, DC,
+,
200 ohms. Check the resistance
of the motor, refer to Note 2.
If the check is good, disconnect the
Drive Motor PWB connector (A7 PI)
from the Drive Motor
PWB. Set
the
Multimeter to
V, DC,
+,
200V.
Measure the voltages at the Motor
PWB connector (A7 PI).
Refer to
Note
1
for voltages at pins A7 PI
-8,7,
6 and 4.
If the check is good, replace the A7
Drive Motor
PWB.
If the check is no
good, replace the A3 Control PWB.
There is
+
26 VDC at pin 8 of A2 P209 of
the LVPSI Driver PWB.
A B C
101 92
7.2 Roll 2 Feed RAP
2-1 82
3050

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents