Xerox 3050 Service Manual page 214

Table of Contents

Advertisement

11.601 LL.611 LL.62 NVM Fault
RAP
NOTE: If
the values entered are not
This RAP
is
used for NVM (Mon Volatile
Memory) problems that are Indicated by a
status code or a message display.
The
Control Panel displays the message
NVM
Fault
Call for Assistance. The Quantity
window may display an 11.60.61, or 62.
The problem may be caused when the NVM
data are corrupted or partially corrupted.
The contents of the NVM does not agree
(
with the checksum, or the contents of the
2.
NVM does not agree with the shadow
contents.
1L.60
-
This status code indicates corrupted
data in
NVM.
Perform steps
1
thru 4 of the
procedure.
11.61
-
This status code is an indication that
an older version of firmware has been
installed. Ensure that the newest version of
Firmware has been installed. If the problem
persists, perform steps 1 thru 4 of the
procedure.
11.62
-
This status code indicates an Auditron
NVM problem. Enter the special test code
10370) to reset Auditron values to default.
Procedure
The purpose of this procedure
i s
t o restore
the copier to normal operation condition.
Refer to the SPECIAL
TEST
codes located in
Sectlon
6
while performing this procedure.
Enter the following SPECIAL TEST codes
retained, replace the NVM chip and
and record the corresponding data
perform steps 2
-
4 again.
values displayed on the control panel:
102611
Country Configuration value
[0360=2]
Electronic Billing Meters
value
108601
Registration value
(08621
Cut length value
[0921-3)
Illumination (Exposure) value
[0921-41
Toner Control value
Enter the SPECIAL TEST code, (US0
copiers 10360-11, EO copiers [0360~3)) in
order to reset the contents of the NVM
t o the factory default values.
Compare the values recorded in step 1 to
previously recorded values for this
machine. Enter the codes listed in step
1
and change the default values as
required.
NOTE: If any value recorded in step
I
appean to be incorrect, use the
previously recorded value. If there is no
previously recorded value, retain the
default value.
Check/ adjust the following:
ADJ 5.1
Copy Size Adjustment
ADJ 8.1
Image Registration
ADJ
8.2
Auto Length
ADJ 9.2
Electrostatic Series
ADJ 10.1
Fuser Temperture
41 96
L L . 6 0 1
LL.611
LL.62
NVM Fault RAP
2.1 22
3050

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents