STEP 3 B: Do not touch the wiping
edge o f the cleaner blade with your
fingers.
3. (Figure
6): lnstall the Cleaner Blade Seal.
C
ENSURE THAT
THE LOCKING
EDGE OF THE
CLEANER BLADE
SEAL IS
POSITIONED AS
SHOWN
INSIDE EDGE OF RETAINER
-
CLEANER
BLADE SEAL
INSTALL THE
MOVE FULLY TO THE
CLEANING BLADE
Figure 6. Install the Cleaner Blade Seal
STEP4: Apply the zinc stearate
5.
(Figure
6):
lnstall the Cleaner Blade
before installing the cleaner blade
Assembly.
assembly into the xerographic
module t o prevent contamination to
6. The remainder of the replacement is the
the charge corotronlerase lamp.
reverse of the removal procedure.
f+h
Apply a light coating of Zinc Stearate t o
the Cleaner Blade.
q!J
INSTALL THE CLEANER BLADE
ASSEMBLY
I
A
MOVE THE SEAL
ASSEMBLY WHILE
DOING THE STEP 0
Figure 6. Install the Cleaner Blade Assembly
7. Check the Cleaner Blade Solenoid (ADJ
9.1).
3/93
3050
4-73
REP 9.4