ADJ 9.1 Cleaner Blade Solenoid
Purpose
The purpose is t o adjust the Cleaner Blade
Solenoid t o ensure that the Cleaner Blade
applies the correct force t o clean the Drum.
Prerequisite
Check the Level of the Copier (ADJ 14.1).
1.
Rotate the Control Console and remove
the Document Handler.
2. Lift
the Document Feed-in Shelf.
3.
Enter the diagnostic mode.
Ensure that all the interlocks are closed.
4.
Enter the code
(09131
t o energize the
Cleaner Blade Solenoid.
Q
STEP 5
B: If the solenoid is at
0.050
inch
(1.3 mm) this ChecklAdjust is complete;
proceed to step 6. If the solenoid needs
adjustment, continue with Step 5 C.
5.
(Figure 2):
Check/Adjust
the
Solenoid.
6. Exit the diagnostic mode.
7. Close the Upper Rear Door and the Side
Doors.
INSERT A 0.050 INCH ( 1.3 mm)
FEELER GAGE THROUGH THE
DIMENSION
"
LOOSEN
SCREWS ( 2 )
Figure
2. Adjust
the Solenoid
-
3193
3050
4-1 27
ADJ 9.1