Alcatel-Lucent 7705 Service Manual page 257

Service aggregation router os
Hide thumbs Also See for 7705:
Table of Contents

Advertisement

eth-test-enable
Syntax
[no] eth-test-enable
Context
config>service>epipe>sap>eth-cfm>mep
Description
This command enables an Ethernet (signal) test (ETH-Test) on a MEP. When enabled, the test runs in
the background. This command applies to Y.1731 SAP MEPs only.
For this test, operators must configure ETH-Test parameters on both sender and receiver nodes. The
ETH-Test can then be run using the following OAM command:
A check is done on the provisioning and the test commands to ensure that the MEP is a Y.1731 MEP.
If the MEP is not a Y.1731 MEP, the operation fails and an error message in the CLI and SNMP will
indicate the problem. A Y.1731 MEP has domain format none and association format icc-based.
The no form of the command disables the ETH-Test on a MEP.
Default
enabled
test-pattern
Syntax
test-pattern {all-zeros | all-ones} [crc-enable]
no test-pattern
Context
config>service>epipe>sap>eth-cfm>mep>eth-test-enable
config>service>epipe>spoke-sdp>eth-cfm>mep>eth-test-enable
Description
This command configures the test pattern for ETH-Test frames.
The no form of the command removes the values from the configuration.
Parameters
all-zeros | all-ones — specifies to use all zeros or all ones in the test pattern
crc-enable — specifies to generate a CRC checksum
7705 SAR OS Services Guide
oam eth-cfm eth-test mac-address mep mep-id domain md-index
association ma-index [priority priority] [data-length data-
length]
Default
all-zeros
VLL Services
Page 257

Advertisement

Table of Contents
loading

Table of Contents