Alcatel-Lucent 7705 Service Manual page 242

Service aggregation router os
Hide thumbs Also See for 7705:
Table of Contents

Advertisement

VLL Services Command Reference
revert-time
Syntax
revert-time [revert-time | infinite]
no revert-time
Context
config>service>apipe>endpoint
config>service>cpipe>endpoint
config>service>epipe>endpoint
config>service>ipipe>endpoint
Description
This command configures the time to wait before reverting back to the primary spoke SDP defined on
this service endpoint, after having switched over to a backup spoke SDP after a failure of the primary
spoke SDP.
Note: The infinite option (for non-revertive behavior) does not apply to Cpipes.
Parameters
revert-time — specifies the time, in seconds, to wait before reverting to the primary SDP
infinite — causes the endpoint to be non-revertive
standby-signaling-master
Syntax
[no] standby-signaling-master
Context
config>service>apipe>endpoint
config>service>cpipe>endpoint
config>service>epipe>endpoint
config>service>ipipe>endpoint
Description
This command sends the pseudowire standby bit (value 0x00000020) to the targeted LDP (TLDP)
peer whenever a spoke-SDP of the endpoint is selected as a standby (see
informs the far end that the pseudowire is not currently active.
Default
no standby-signaling-master
service-mtu
Syntax
service-mtu octets
no service-mtu
Context
config>service>apipe
config>service>cpipe
config>service>epipe
config>service>ipipe
Page 242
Values
0 to 600
precedence
7705 SAR OS Services Guide
). This bit