A
General fundamentals on system parameterisation
A.1.2
Signal status in the event of an error (fail safe)
Fundamentals
With the aid of the so-called fail safe parameterisation, the signal status which the outputs are to as
sume in the event of fieldbus communication errors, can be determined (fail safe status). In this way, a
defined machine/system status is to be created in the event of fieldbus communication errors (e.g.
failure of the higher-order controller).
Warning
Uncontrolled movements of the machine and the system resulting from manipulation of
signal states.
Injury to people, damage to the machine and system
Note information on Fail Safe parameterisation in the CPX system description
(è Tab. 1).
Parameterisation
With the MSE6-E2M, fail safe parameterisation can be used for output data.
By means of the system parameter "Fail safe", you can globally define the signal status which the out
puts are to assume in the event of fieldbus communication errors, e.g. in the event of:
– Communication failure (network interruption, PLC failure)
– Communication stop.
System parameter
Fail safe
Tab. A.4
System parameter "Fail-safe"
Festo – MSE6-E2M-SY-EN – 1703d – English
Settings
Reset outputs
(presetting)
Hold last state
Assume Fault mode
value
Description
Reset all outputs, shut-off valve switches to the
"Pressurisation" state
Retain current signal status for all outputs
Accept the signal status defined for the relevant
channel
107