Commissioning, Diagnostics And Operational Functions - Festo MSE6-E2M Original Instructions Manual

Energy efficiency module
Table of Contents

Advertisement

2
Overview
Flow recording
The MSE6-E2M continuously records the flow, prepares the data and makes it available cyclically.
To detect excessive flow rates, the MSE6-E2M offers the option of parameterising limit values for the
flow. If the parameterised limit value is exceeded, the device will output a diagnostic message.
Consumption recording
The MSE6-E2M determines the compressed air consumption by recording the system flow rate. The
user has the option of using signaling to record the compressed air consumption over a specific period
of time.
2.2

Commissioning, diagnostics and operational functions

The system response of the MSE6-E2M can be adapted to the relevant application. The MSE6-E2M
provides extensive functions for commissioning, diagnostics and operation.
Commissioning and operational functions
The MSE6-E2M is delivered with preset parameters.
The behaviour of the MSE6-E2M can be adapted to the respective requirements through parameterisa­
tion. The following behaviour can be influenced, for example, by accessing the internal parameters:
– The diagnostic behaviour by enabling maskable diagnostic messages
– Specification of the units and the measuring interval
– Setting of limit values
– The operating method of the diagnostic memory.
Warning
When the MSE6-E2M is replaced, a different parameterisation will result in different
behaviour
Injury to people, damage to the machine and system
If the "M" LED (Modify) is lit continuously, the parameterization of the MSE6-E2M is not
restored automatically by the higher-level controller after a replacement.
• Before replacing the MSE6-E2M, check which settings are required and restore them
after the replacement.
An overview of the different parameters can be found in chapter 7 of the commissioning
description for the energy efficiency module (è MSE6-E2M-IN-...). A detailed description
of the parameters can be found in chapter 7.
Festo – MSE6-E2M-SY-EN – 1703d – English