Input Word Em.1 "Consumption" [Consumption]; Input Word Em.2 "Pressure P2" [Pressure P2] - Festo MSE6-E2M Original Instructions Manual

Energy efficiency module
Table of Contents

Advertisement

6
Input/output data
6.2.3

Input word Em.1 "Consumption" [Consumption]

The input word is shown in Motorola format (MSB-LSB).
Depending on the parameterised air consumption unit and the parameterised flow standard, the air
consumption measured is transferred to the higher-order controller as the input word (2 bytes, 16 bits).
The presetting of the module parameter "Unit Consumption" is "l", the presetting of the module para­
meter "Unit Flow standard" is "DIN 1343". Independent of the parameterised unit, the maximum con­
sumption value displayed is 65535. If there is a change to the parameter values "Flow unit" or "Flow
standard", the consumption is reset to the value "0". If there is a change to the parameter value "Con­
sumption unit", the consumption value remains unchanged and is converted correspondingly.
Data format of input word, "16 bits, right-justified"
D15 D14 D13 D12 D11 D10 D9
B15 B14 B13 B12 B11 B10 B9
MSB
Abbreviations used
B0 ... B15:
Consumption measurement value
D0 ... D15
16 bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 6.5
Data format of input word, "16 bits, right-justified"
6.2.4

Input word Em.2 "Pressure P2" [Pressure P2]

The input word is shown in Motorola format (MSB-LSB).
Depending on the parameterised pressure unit, the pressure P2 is transferred to the higher-order con­
troller as the input word (2 bytes, 16 bits).
The presetting of the module parameter "Unit Pressure" is "mbar". The input word is always specified
in the data format "Sign + 15 bits". The pressure value is stored in the input word as follows.
Data format of input word, "Sign + 15 bits, right-justified"
D15 D14 D13 D12 D11 D10 D9
Sign B14 B13 B12 B11 B10 B9
MSB
Abbreviations used
Sign:
Sign (for data format "Sign + 15 bits" always = 0, i.e. a positive value)
B0 ... B14:
Pressure value
D0 ... D15
16 bit input data field
MSB/LSB
Most significant bit/least significant bit
Tab. 6.6
Data format of input word, "Sign + 15 bits, right-justified"
Festo – MSE6-E2M-SY-EN – 1703d – English
D8
D7
D6
D5
B8
B7
B6
B5
D8
D7
D6
D5
B8
B7
B6
B5
D4
D3
D2
D1
B4
B3
B2
B1
D4
D3
D2
D1
B4
B3
B2
B1
D0
B0
LSB
D0
B0
LSB
65