Setting The Dil Switch - Festo MSE6-E2M Original Instructions Manual

Energy efficiency module
Table of Contents

Advertisement

4
Commissioning
4.5.3

Setting the DIL switch

Note
The bus node includes electrostatically sensitive devices.
Malfunction or damage to the electronics
• Do not touch any components.
• Observe the handling specifications for electrostatically sensitive devices.
You can set the following parameters with the DIL switches:
– Operating mode and protocol (The MSE6-E2M only supports the Remote I/O operating mode)
– Diagnostics mode
– IP addressing.
1. Switch off power supply.
2. Unscrew and remove the fastening screws of the cover
3. Remove cover.
è 3 DIL switches appear.
4. Use DIL switch 1 to set operating mode and protocol.
5. Set diagnostic mode using DIL switch 2.
6. Setting the IP addressing with DIL switch 3.
7. Fit cover.
8. Tighten mounting screws of the cover at first by hand and then with 0.4 Nm ± 10 %.
1
1
Setting operating mode and protocol
(DIL switch 1)
2
DIL switch 2: Diagnostic mode
Fig. 4.13
DIL switches on bus node CPX-FB36
Festo – MSE6-E2M-SY-EN – 1703d – English
.
ON
ON
1
2
1
2
3
DIL switch 3: IP addressing
2
3
43

Hide quick links: