Festo MSE6-E2M Original Instructions Manual page 58

Energy efficiency module
Table of Contents

Advertisement

5
Measurement and control functions
The status of the timer is available in the "Auto blocking timer status bits" input (Em.3.4-3.5) and can
assume the following values:
RESET:
The timer is reset and not started,
the shut-off valve is in the "Pressurisation" state.
RUN:
Timer is started,
the time delay has not yet elapsed,
the shut-off valve is in the "Pressurisation" state.
UP:
The time delay has elapsed,
the shut-off valve is in the "Blocking" state.
Am.0.1:
Auto blocking control bit
Am.0.0:
Blocking control bit
Auto blocking
Flow limit value
Em.3.4-3.5:
Auto blocking timer status bits
Em.3.0
Shut-off valve status bit
Fig. 5.8
Behaviour of automatically-controlled blocking
58
Active
Inactive
Active
Inactive
Not reached
Complied with
RESET
Blocking
Pressurisation
Auto blocking
Delay
RUN
Festo – MSE6-E2M-SY-EN – 1703d – English
UP