Festo MSE6-E2M Original Instructions Manual page 42

Energy efficiency module
Table of Contents

Advertisement

4
Commissioning
Network interface on bus node CPX-FB36
There are two 4-pin, D-coded M12 sockets on the bus node CPX-FB36 for the network connection.
Network interface X1
Socket, M12
Pin
D-coded
2
1
2
3
1
3
4
Housing
4
Tab. 4.19 Pin allocation of network interface X1 on bus node CPX-FB36
Network interface X2
Socket, M12
Pin
D-coded
2
1
2
3
1
3
4
housing
4
Tab. 4.20 Pin allocation of network interface X2 on bus node CPX-FB36
Connect the bus node to the network with a Festo plug connector (NECU-
M-S-D12G4-C2-ET). The plug connector is designed for Ethernet lines with cable diamet­
ers of 6 ... 8 mm.
42
Signal
Explanation
TD+
Transmission data (transmit data, TD) +
RD+
Receive data (receive data, RD) +
TD–
Transmitted data –
RD–
Received data –
Shield/FE
Shield/functional earth
Signal
Explanation
RD+
Receive data (receive data, RD) +
TD+
Transmission data (transmit data, TD) +
RD–
Received data –
TD–
Transmitted data –
Shield/FE
Shield/functional earth