4
Commissioning
Setting the operating mode (DIL switch 1)
The MSE6-E2M with the bus node CPX-(M)-FB33/34/35 only supports the operating
mode Remote I/O (factory setting).
All switch elements of the DIL switch 1 must be in the OFF position.
Setting of DIL switch 1
DIL 1.1: OFF
DIL 1.2: OFF
(Factory setting)
DIL 1.1: ON
DIL 1.2: OFF
DIL 1.1: OFF
DIL 1.2: ON
DIL 1.1: ON
DIL 1.2: ON
Tab. 4.14 Setting the operating mode with DIL switch 1
Setting the diagnostic mode (DIL switch 2)
Setting of DIL switch 2
DIL 2.1: OFF
DIL 2.2: OFF
(factory setting)
DIL 2.1: OFF
DIL 2.2: ON
DIL 2.1: ON
DIL 2.2: OFF
DIL 2.1: ON
DIL 2.2: ON
1) Status bits occupy 1 byte of address space (8 I bits)
2) I/O diagnostics interface occupies 4 bytes of address space (16 I and 16 O bits)
3) Revision 21 and above
Tab. 4.15 Set diagnostic mode using DIL switch 2
36
Setting the operating mode
Remote I/O operating mode
All functions of the MSE6-E2M are controlled directly by the
controller or by a higher-level PLC.
Is not supported by the MSE6-E2M.
The DIL switch elements 1.1 and 1.2 must be in the OFF posi­
tion.
Setting the diagnostic mode
(in remote I/O operating mode)
I/O diagnostics interface and status bits are switched off or
diagnostic mode is set via the hardware configuration of the
configuration software
(+ 0 byte I/0 Byte O)
Status bits are switched on
1)
(+ 1 byte I/0 byte O)
I/O diagnostics interface is switched on
2)
(+ 2 bytes I/2 bytes O)
Reserved for future extensions
3)
Festo – MSE6-E2M-SY-EN – 1703d – English