Diagnostics and error handling
[SF] – System Failure
LED (red)
Sequence1
ON
OFF
flashes
ON
OFF
ON
OFF
ON
OFF
off
1) The "SF" LED flashes depending on the error class.
Error class 1 (simple error): 1 flash, pause
Error class 2 (error)
Error class 3 (serious error): 3 flashes, pause
Tab. 8.4 LED indicator [SF] – System failure
[M] – Parameterisation modified or Force active (modify)
LED (yellow)
Sequence
ON
OFF
lights up
ON
OFF
flashes
ON
OFF
off
1) Indication of the Force function (LED flashing) has priority over indication of the setting for the system start (LED lights up).
Tab. 8.5 LED indicator [M] – Parameterisation modified or Force active (modify)
86
)
Significance
Simple fault/information
(error class 1)
Error
(error class 2)
Serious error
(error class 3)
No error
2 flashes, pause
Significance
System start with saved parameterisation has been set.
The parameters are saved remanently; external parameterisation is
1)
disabled
Caution when replacing the MSE6-E2M with saved parameterisation.
Parameterisation is not carried out automatically by the higher-order
controller on replacement.
• Before replacement, note required settings and restore them after
replacement if required.
The Force function is enabled.
System start with default parameterisation (factory setting) is set;
external parameterisation is possible (presetting).
Remedy
Description of the error numbers
(è 8.4 Error numbers)