Festo MSE6-E2M Original Instructions Manual page 77

Energy efficiency module
Table of Contents

Advertisement

7
Parameterisation
Module parameter: Unit Consumption
Function no.
4828 + m * 64 + 8
Description
Specifies the unit for all consumption-related input values and parameters.
Bit
Bit 4, 5:
All other bits are reserved.
Values
Bit 5
4 Value
0
0
0
0
1
1
1
0
2
1
1
3
Memo
If parameterisation error monitoring is active (P0.7), invalid values will lead to
the parameterisation error FN29 è Tab. 8.19
Tab. 7.11 Unit Consumption
Module parameter: Unit Flow standard
Function no.
4828 + m * 64 + 8
Description
Specifies the flow standard for all flow and consumption-related input values
and parameters.
Bit
Bit 6, 7:
All other bits are reserved.
Values
Bit 7
6
Value
0
0
0
0
1
1
1
0
2
1
1
3
Memo
If parameterisation error monitoring is active (P0.7), invalid values will lead to
the parameterisation error FN29 è Tab. 8.19
Tab. 7.12 Unit Flow standard
Festo – MSE6-E2M-SY-EN – 1703d – English
Unit Consumption
Significance
l (presetting)
3
m
scf
Not permissible
Flow standard
Significance
DIN 1343 (presetting)
ISO 2533
ISO 6358
Not permissible
[Unit Consumption]
m = module number (1)
[Unit Flow standard]
m = module number (1)
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents