C
Parameters and data
System data: CPX structure
Function no.
0
Description
Specifies whether the current CPX structure corresponds to the saved CPX struc­
ture.
Bit
Bit 4
Values
CPX structure
Bit 4 Description
0
Equal
1
Unequal
è also "System start" system parameter
Comment
Tab. C.35
CPX structure
System data: Operator unit
Function no.
0
Description
Specifies whether or not an operator unit is connected.
Bit
Bit 5
Values
Operator unit
Bit 5
Description
0
No operator unit is connected
1
Operator unit connected
Comment
Information for the higher-order controller.
If necessary for test purposes, a parameterisation carried out using an operator
unit is to be cancelled by reloading the parameters, or forcing by higher-order
PLC/IPC is to be blocked whilst an operator unit is connected.
Tab. C.36
Operator unit
System data: Force mode
Function no.
0
Description
Specifies whether Force is disabled or enabled.
Bit
Bit 6
Values
Force mode
Bit 6
Description
0
Disabled
1
Enabled
è also "Force mode" system parameter
Comment
Tab. C.37
Force mode
134
[CPX structure]
[equal]
[unequal]
[Handheld]
[connection OK]
[Force mode]
[Disabled]
[Enabled]
Festo – MSE6-E2M-SY-EN – 1703d – English