C
Parameters and data
Diagnostic memory parameters: Fault end filter
Function no.
3484
Description
Diagnostic memory filter with which can be used to determine whether running
errors are to be recorded or not.
Bit
Bit 3
Values
Fault end filter
Bit 3
Description
0
Record running errors (end of error) (filter inactive,
presetting)
1
Do not record running errors (fault end) (filter active)
Comment
By recording the running faults it can be determined how long the error has exis
ted. Incoming and running faults each represent one entry. With running faults,
the error number "0" is entered. A maximum of 40 entries are saved together.
Tab. C.13
Fault end filter
Diagnostic memory parameters: Error number filter
Function no.
3484
Description
With this diagnostic memory filter you can:
– Suppress the recording of a desired error message
– Record exclusively a desired error message.
Bit
Bit 4, 5
Values
Fault numbers filter
FN = Error number
Bit 5
4 Description
0
0
Error number filter inactive (presetting)
0
1
Record only defined FN
1
0
Do not record defined FN
1
1
Reserved
Comment
The error number is determined by means of the diagnostic memory parameter
"Error number" (function no. 3487).
Tab. C.14
Error number filter