Parameters and data
Module diagnostic data: Number of the first faulty channel
Function no.
2008 + m * 4 + 0
Description
Specifies the number of the faulty channel (bits 0...5)
Bit
Bit 7 6 5 ... 0:
Values
Bit 0...5:
Bit 6:
Bit 7:
Comment
With the aid of the module number of the faulty module (è Tab. C.26), you can
ascertain the function number of the relevant diagnostic data.
Tab. C.29
Number of the first faulty channel
Module diagnostic data: Module error number
Function no.
2008 + m * 4 + 1
Description
Error number
Bit
Bit 0 ... 7:
Values
0 ... 255
Possible error messages è 8.4.
Comment
Tab. C.30
Module error number
Module diagnostic data: Information 2 (reserved)
Function no.
2008 + m * 4 + 2
Description
Reserved
Tab. C.31
Information 2 (reserved)
Module diagnostic data: Information 3 (reserved)
Function no.
2008 + m * 4 + 3
Description
Reserved
Tab. C.32
Information 3 (reserved)
132
Description
0 0 0 ... 63: No. of the 1st defective output channel
1 0 0 ... 63: No. of the 1st defective input channel
0 1 0 ... 63: Module error
1 1 0 ... 63: Reserved
0 ... 63 (Channel number)
0 ... 1
0 ... 1
Error number
(Error number)
m = Module number (1)
m = Module number (1)
m = Module number (1)
m = Module number (1)