8
Diagnostics and error handling
Error
Error
Significance
no.
chan
1)
nel
25
Fault in parametrizing upper limit
[Fault in parametrizing upper limit]
Em.0
An error has occurred in the
setting of the "Upper limit
flow" parameter
Em.2
An error has occurred in the
setting of the "Upper limit
pressure" parameter
Em.3
An error has occurred in the
setting of the "Upper limit
pressure change" paramet
er
26
Fault in actuator supply [Fault in actuator supply]
Am.0
UOUT
beneath the permitted
range
29
Fault in parametrizing [Fault in parametrizing]
Em.0
– Monitor limit values
...
Em.3
– Unit Pressure
– Unit Flow
– Unit Consumption
– Unit Flow standard
– Pressure change sample
Channel-dependent error
distinction
1) m = Module number (1)
2) With active monitoring, the module displays the relevant fault, depending on the parameterisation. Input signals will, however, be
processed further.
3) All electrical module functions are stopped.
4) The parameter values entered will be ignored; the module operates internally with the last valid parameter values.
Tab. 8.19
Module-specific error numbers
Festo – MSE6-E2M-SY-EN – 1703d – English
load voltage supply
/A
startup
time
Remedy
2)4)
Check the parameterisa
tion undertaken and
carry out the paramet
erisation again with the
correct parameters (valid
parameters
è Tab. 7.15).
2)
Check the U
OUT/A
voltage supply and in
crease if required.
Check the cabling of the
load voltage supply and
repair if required.
2)4)
Check the parameterisa
tion undertaken and
carry out the paramet
erisation again with the
correct parameters (val
id parameters è 7.4).
Enable parameter
"Monitoring":
4828 + m * 64 + 0
(bit 7) "Monitoring of
parameterisation
faults" (è Tab. 7.7)
load
"Monitoring":
4828 + m * 64 + 0,
(bit 2) "Monitoring un
dervoltage actuator
supply" (è Tab. 7.7)
"Monitoring":
4828 + m * 64 + 0
(bit 7) "Monitoring of
parameterisation
faults" (è Tab. 7.7)
101