Input/output data

6
Input/output data
6.1

Overview

The MSE6-E2M possesses multiple items of functional module data, which can be replaced with the
higher-order controller using the I/O data presented below.
Data field for
Flow measurement
Consumption measurement
– Measured value
– Function status
– Control/operation
Pressure measurement
Pressure change measurement
Blocking function
– Function status
– Control/operation
Selectable input data
– Input address
– Input data
1) m = 1
Tab. 6.1
Overview of I/O data
6.2

Description of I/O data

6.2.1

Output word Am.0 "Module control" [Modul control]

The output word is shown in Motorola format (MSB-LSB).
In the output word Am.0, the user can control the consumption measurement and the blocking function
of the shut-off valve.
The output value (2 bytes, 16 bits) is transmitted by the higher-order controller.
62
1)
Input word
Em.0
Em.1
Em.3
Em.2
Using selectable input data (è 6.3)
Em.3
Em.4
Em.5
1)
Output word
Am.0
Am.0
Am.1 (è 6.3)