Parameterisation
7.4.1

Modifiable module parameters

Module parameter: Monitor
Function no.
4828 + m * 64 + 0
Description
With the MSE6-E2M, monitoring of individual errors can be independently activ­
ated or deactivated (suppressed).
If monitoring is activated, the error:
– is sent to the bus node
– is displayed by the module common error LED.
Bit Description
2 Monitoring undervoltage of actuator supply
6 Monitoring of limit values
7 Monitoring of parameterisation errors
All other bits are reserved.
Values
1 = active (presetting)
0 = inactive
Memo
Monitoring of parameterisation errors:
Some parameters are checked for non-permitted values during parameterisa­
tion:
– Diagnostics startup limit value
– Units
– Limit values
Tab. 7.7
Monitoring
Module parameters: Monitor limit values startup
Function no.
4828 + m * 64 + 7
Description
Specifies the time after the supply voltage has been switched on, during which
limit monitoring is deactivated.
Bit
Bit 0...7 Monitor limit values startup
Values
bit 2
1
0
Value
0
0
0
0
0
0
1
1
0
1
0
2
0
1
1
3
1
0
0
4
1
0
1
5
1
1
0
6
1
1
1
7
...
8 ... 255
Memo
If parameterisation error monitoring is active (P0.7), invalid values will lead to
the parameterisation error FN29 è Tab. 8.19
Tab. 7.8
Diagnostics startup limit value
Festo – MSE6-E2M-SY-EN – 1703d – English
Significance
0 s
3 s
5 s
10 s (presetting)
30 s
60 s
120 s
300 s
Not permissible
[Monitor]
m = module number
[Monitor Vout/Vval]
[Monitor limit values]
[Monitor parameters]
[Active]
[Inactive]
[Monitor limit values startup]
m = module number (1)
(1)
75