Commissioning
Setting the IP addressing (DIL switch 3)
The type of addressing or the IP address of the MSE6-E2Mis set via DIL switches 3.1 ... 3.8.
Setting of DIL switch 3
DIL 3.1 ... 3.8: OFF
DIL 3.8: OFF
DIL 3.7: ON
DIL 3.6: OFF
DIL 3.5: ON
DIL 3.4: OFF
DIL 3.3: ON
DIL 3.2: ON
DIL 3.1: OFF
DIL 3.1 ... 3.8: ON
Tab. 4.24 Set the IP addressing (DIL switch 3)
46
Setting IP addressing
Dynamic/saved addressing
All DIL switches in the OFF position (factory setting).
When the MSE6-E2Mis switched on, it receives a
dynamic or saved IP address via DHCP/BOOTP.
7
2
= 128
Fixed addressing
6
2
= 64
The host ID of the IP address (4th octet) is set binary
5
coded using DIL switches 3.1 ... 3.8.
2
= 32
4
Permissible range of values: 1 ... 254
2
= 16
3
2
= 8
2
Example:
2
= 4
1
2
1
2
+ 2
+ 2
2
= 2
0
Set IP address: 192.168.1.86
2
= 1
Resetting all IP parameters to factory settings
All DIL switches in ON position.
All IP parameters of the MSE6-E2M are reset to the
factory settings when device is switched on.
4
6
+ 2
= 2 + 4 + 16 + 64 = 86 (host ID)