Applicable documents Applicable documents All available documents for the product è www.festo.com/pk. Specified standards Standard Title EN ISO 13849-1:2008-06 Safety of machinery - Safety-related parts of control systems Part 1: General principles for design EN ISO 13849-2:2008-06 Safety of machinery - Safety-related parts of control systems...
– Accessories è www.festo.com/catalogue. – Spare parts èwww.festo.com/spareparts. Service Contact your regional Festo contact person if you have technical questions è www.festo.com. Product overview Design 5.1.1 Product design The product corresponds to category 3 + 4 with a maximum achievable performance level e in accord- ance with EN ISO 13849-1.
Another safety function of the product is the pro- tection against unexpected start-up after EN 1037. Via the safety-related electrical connection, the product is connected as a slave to the AS-i-Safety at Work environment without additional devices. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Page 7
AS-i safety monitor. This transmission takes place using a special security protocol. In the event of a stop request or a defect, the AS-i safety monitor safely switches off the system in pro- tective mode with a reaction time of max. 40 ms. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
For the safety functions, the product has control characteristics with which a performance level e can be achieved. This product has been designed and manufactured in accordance with the fundamental and reliable safety principles of EN ISO 13849-2. The following requirements apply to the manager: Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Observe minimum distance of 15 mm below the silencer è Fig.4. The free space ensures the exhaust can escape. – Place product as close as possible to the installation site – The product can be mounted in any position Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Incorrect installation in the service unit combination can result in failure of the exhaust safety func- tion. • Only devices that do not impair the exhaust process, even after a possible malfunction of the device, may be placed downstream from the MS6-SV-…. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
– Make sure exhaust has no obstacles: do not block silencer or port 3. For the product, an adapter (from thread size NPT1 to G1) must also be mounted between the silencer and the product. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
The following must be observed for branch lines: – The maximum total length of the AS-i bus: 100 m without repeater/extender – The cable length of the load voltage connection (depending on the current consumption and the fluctuations of the load voltage). Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Page 13
Pin 4: n. c. Pin 4: addressing contact + Tab. 3 Connection AS-i-Interface-Bus Seal unused connections with suitable protective caps è www.festo.com/catalogue. AS-Interface addresses Before commissioning, a non-safety-related slave address and a safety-related slave address must be assigned to the product.
Page 14
Value xx Switching cycle counter valve Value xx Switching cycle counter valve Value xx Switching cycle counter valve (high Byte) Value xx Monthly counter Value xx Tab. 8 Data format of diagnostic AS-i object 00 Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Page 15
Assigning the AS-i address Recommendation: use the addressing device ASI-PRG-ADR with connecting cable KASI-ADR from Festo. The addressing device scans the slave connected to the addressing device. Addressing for safety-related slave: 1. Insert the AS-i configuration plug CACC-CP-AS into the M12 bushing.
The output pressure rises depending on the throttle setting è 14.6 Filling flow. When the switch-through pressure is reached (approx. 50% of operating pressure p1), the valve’s main seat opens è 14.5 Switch-through pressure/filling time. The product is ready for operation (safety function safe venting). Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Illuminated green AS-i interface voltage applied, no error Illuminated red AS-i address not set (equals 0) Illuminated red Failure of bus communication, e. g. watchdog expired Flashes green/red Error in exhaust valve Tab. 10 Diagnostics LED AS-i Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
2. Separate the applicable connections from the product. When using a commercially available silencer, the cushioning body may become clogged, which can result in reduced reduced exhaust performance and back pressure. • Use the safety silencer that belongs to the device è www.festo.com/catalogue. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Degree of protection IP65 with plug socket Operating voltage Operating voltage range DC AS- 22.0 31.6 … Interface Switching time Switching time off [ms] Switching time on [ms] Duty cycle Tab. 14 Technical data, electrical Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
If the outlet pressure p2 has reached approx. 50 % of the operating pressure p1, the valve opens and full operating pressure p1 is applied at the outlet. Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
1.2 … 2.8 bar is permissible. 14.6 Filling flow Flow rate qn dependent on the number of rotations n of the flow control screws p1: 4 bar p1: 8 bar p1: 6 bar p1: 10 bar Fig. 9 Flow diagram Festo — MS6(N)-SV-...-E-ASIS — 2019-05a...
Page 26
Copyright: Festo SE & Co. KG Ruiter Straße 82 73734 Esslingen Germany Reproduction, distribution or sale of this document or communic- Phone: ation of its contents to others without express authorization is +49 711 347-0 prohibited. Offenders will be liable for damages. All rights...