Types Of Parameters - Festo MSE6-E2M Original Instructions Manual

Energy efficiency module
Table of Contents

Advertisement

7
Parameterisation
7.3

Types of parameters

The parameters are preset at the factory. These presettings can be used for a large number of applica­
tions. Through parameterisation, the behaviour of the MSE6-E2M can be adapted to each particular
application.
The options available depend on the network protocol used. You can find information on
this in the description of the bus node (è Tab. 1).
A distinction is made between the following types of parameters:
Types of parameters
System parameters
Module parameters
Diagnostic memory parameters
Tab. 7.1
Types of parameters
Basic principles of using the parameters can be found in Appendix (è C Parameters and data). The
tables below give a brief overview of the most important parameters.
System parameters
Diagnostics monitoring on under­
voltage in the actuator technology
System start
Tab. 7.2
System parameters
Module parameters
Modifiable module parameters
Diagnostic monitoring with:
– Undervoltage of actuator supply
– Limit value violation
– Parameterisation errors
Monitor limit values startup
Units
72
Description
Influence the behaviour of the complete system
Influence the behaviour of a particular module
Influence the mode of operation of the internal diagnostic
memory
Description
Switching on or off the monitoring of undervoltage of the load
voltage supply.
Specifies the start-up behaviour of the MSE6-E2M.
Description
The monitoring functions shown alongside can be switched on
or off on the module side.
Defines the period in which limit monitoring remains deactiv­
ated after the power supply is switched on. For flow monitor­
ing, the diagnostics delay also applies after each change into
the "Pressurisation" state.
Defines the units, in which individual pieces of input data are
shown and/or processed. In addition, the flow standard is set
using this parameter.
Festo – MSE6-E2M-SY-EN – 1703d – English