4
Commissioning
Basic addressing rules
Bus nodes:
– The bus node occupies 0 inputs and 0 outputs if the diagnostic mode is not active.
– Active status bits occupy 8 input bits.
– An active I/O diagnostic interface occupies 16 input and 16 output bits.
Network:
– The address assignment of the inputs is independent of the address assignment of the outputs.
– Addressing is carried out in bytes.
Device description file (GSD file)
A device description file (GSDML file) is needed for configuration and parameterisation of the bus node.
The device description file contains all information required to integrate the module into the higher-or­
der controller.
The current device description file is available on the Festo Support Portal
(è www.festo.com/sp).
Setting up automation project and controller
1. Start the controller software.
2. Create a new project: [File] , [New...].
3. Enter a project name (e.g. MSE6-E2M_PROFINET).
4. Insert the controller used: [Insert] , [Station] , [...] (e.g. SIMATIC 300 Station).
5. Extend project tree and select controller.
6. Open hardware configuration window: [Edit] , [Open Object].
Installing the device description file
1. Open Festo Support Portal (è www.festo.com/sp).
2. Enter search term "GSDML CPX".
3. Select, save and unzip current device description file on the "Software" tab.
4. Install the device description file: [Options] , [Install GSD File ...].
5. Update hardware catalogue: [Options] , [Update Catalog].
è All available CPX modules appear in the hardware catalogue under:
\PROFINET IO\Additional Field Devices\Valves\Festo MSE Air Supply
Setting up automation project and controller
1. Open hardware catalogue: [View] , [Catalog].
2. Extend control in hardware catalogue (e.g. SIMATIC 300) and folder structure.
3. Extend the folder "RACK-300".
4. Insert profile rail in controller.
5. Reproduce the controller configuration using the components from the rack rail table in the hard­
ware catalogue.
Row 1 (Slot 1) is reserved (e.g. for a power supply unit).