Sign In
Upload
Manuals
Brands
Festo Manuals
Control Unit
CPX-FB23
Festo CPX-FB23 Manuals
Manuals and User Guides for Festo CPX-FB23. We have
3
Festo CPX-FB23 manuals available for free PDF download: Electronic Manual, Description, Manual
Festo CPX-FB23 Electronic Manual (122 pages)
Field bus node, Field bus protocol: CC-Link
Brand:
Festo
| Category:
Touch terminals
| Size: 2.31 MB
Table of Contents
Table of Contents
5
Designated Use
7
Target Group
7
Service
7
Notes on the Use of this Manual
8
Important User Instructions
9
Notes on the Use of this Manual
11
Installation
15
General Instructions on Installation
18
Settings on the CPX Field Bus Node
21
Removing/Fitting the DIL Switch Cover
21
Setting the DIL Switches
22
Connecting the Field Bus
33
Field Bus Cable
33
Field Bus Baud Rate and Field Bus Length
35
Pin Assignment of Field Bus Interface
37
Connecting the Field Bus
38
Bus Termination with Terminating Resistors
42
Pin Assignment for Power Supply
43
Commissioning
45
Configuration and Addressing
48
Number of Inputs/Outputs
48
Addressing Rules
52
Number of Assigned Stations
54
Addressing Examples (Examples of Address Assignment)
55
Address Assignment after Extension/Conversion
65
CC−Link Memory Mapping
67
Bus Configuration and Addressing
72
Parametrizing
79
Commissioning the CPX Terminal on the Field Bus
82
HOLD/CLEAR and Fail Safe
83
RUN/PAUSE and STOP of the Master
84
RAS Function
85
Diagnosis and Error Treatment
87
Overview of Diagnostic Possibilities
90
Fault Messages of the Field Bus Node CPX−FB23
91
Diagnosis Via Leds
92
Normal Operating Status
93
Cpx−Specific Leds
94
CC−Link−Specific Leds
97
Possible Operating States of the CPX Leds
99
Diagnosis Via CC−Link
100
I/O Diagnostic Interface
102
Fault Treatment
103
A.1 Technical Specifications of Field Bus Node Type CPX−FB23
107
A.2 Accessories
109
A.3 Default Parametrizing of the CPX Terminal
110
B.1 Index
118
Advertisement
Festo CPX-FB23 Description (85 pages)
Terminal CPX, Bus node
Brand:
Festo
| Category:
Control Unit
| Size: 0.63 MB
Table of Contents
Table of Contents
3
1 Safety and Requirements for Product Use
7
Safety
7
General Safety Information
7
Intended Use
7
Requirements for Product Use
8
Technical Prerequisites
8
Qualification of the Specialized Personnel (Requirements for the Personnel)
9
Range of Application and Certifications
9
2 Installation as Function Module F24
10
General Instructions on Installation
10
Electrical Connection and Display Components
11
Dismantling and Mounting
12
Dismantling
12
Mounting
13
Settings of the DIL Switches on the Bus Node
13
Removing and Attaching the DIL Switch Cover
13
Arrangement of the DIL Switches
14
Setting the DIL Switches
14
Setting the Operating Mode
15
Setting the Baud Rate
16
Configuration as Function Module F24 or F23
17
Setting the CC-Link Slave Address
18
Setting of Mapping Optimisation
21
Setting the HOLD/CLEAR Function
23
Setting the System Diagnostics
24
Connecting the Fieldbus
25
Fieldbus Cable
25
Fieldbus Baud Rate and Fieldbus Length
26
Pin Allocation of the Fieldbus Interface
28
Connecting the Fieldbus
28
Fieldbus Connection with Terminating Resistors
31
Pin Allocation of Power Supply
32
3 Commissioning as Function Module F24
33
General Instructions for Commissioning
33
Configuration and Addressing
33
Number of Inputs/Outputs
33
Addressing Rules
35
Addressing Examples (Examples of Address Assignment)
37
Address Assignment after Extension/Conversion
42
CC-Link Memory Mapping
42
Fieldbus Configuration
44
Parameterisation
45
Parameters of the CPX Terminal
46
Parameterisation Concepts
47
Commissioning of the CPX Terminal on the Fieldbus
48
HOLD/CLEAR and Fail Safe
48
RUN/PAUSE and STOP of the Master
48
RAS Function
48
Operation as Function Module F24 to CC-Link Master Version
49
4 Diagnostics and Error Handling
50
General Instructions on Diagnostics and Error Handling
50
Summary of Diagnostics Options
51
Error Messages of the Bus Node CPX-FB23-24
52
Diagnostics Via Leds
53
Standard Operating Status
54
CPX-Specific Leds
55
CC-Link-Specific Leds
57
Possible Operating Statuses of CC-Link-Specific Leds
58
Diagnostics Via Fieldbus CC-Link
59
Status Bits
59
I/O Diagnostics Interface
60
5 Function Module F23
61
General Instructions
61
Installation
61
Setting the Operating Mode
62
Setting the Number of Stations Per Slave / Number of I/O Bytes
63
Commissioning
64
Configuration and Addressing
64
Address Assignment after Extension/Conversion
72
CC-Link Memory Mapping
72
Fieldbus Configuration
75
Parameterisation
75
Commissioning of the CPX Terminal on the Fieldbus
75
RUN/PAUSE and STOP of the Master
76
General Notes on Diagnostics and Error Handling
76
A Technical Appendix
77
Technical Data
77
Default Parameterisation
78
A.2 Default Parameterisation
78
Accessories
79
A.3 Accessories
79
B Glossary
80
List of Abbreviations
80
Festo CPX-FB23 Manual (84 pages)
Bus node Fieldbus protocol CC-Link
Brand:
Festo
| Category:
Touch terminals
| Size: 0.79 MB
Table of Contents
Cpx-Fb23, Cpx-Fb23-24
2
Table of Contents
3
1 Safety and Requirements for Product Use
7
Safety
7
General Safety Instructions
7
Intended Use
7
Requirements for Product Use
8
Technical Requirements
8
Qualification of the Specialists (Requirements for the Personnel)
9
Range of Application and Certifications
9
2 Installation as Function Module F24
10
General Instructions on Installation
10
Electrical Connection and Display Components
11
Dismantling and Mounting
12
Dismounting
12
Mounting
13
Settings of the DIL Switches on the Bus Node
13
Removing and Attaching the DIL Switch Cover
13
Arrangement of the DIL-Switches
14
How to Set the DIL Switch
14
Setting the Operating Mode
15
Setting the Baud Rate
16
Configuration as Function Module F24 or F23
17
Setting the CC-Link Slave Address
18
Setting of Mapping Optimisation
21
Setting the HOLD/CLEAR Function
23
Setting the System Diagnostics
24
Connecting the Fieldbus
25
Fieldbus Cable
25
Fieldbus Baud Rate and Fieldbus Length
26
Pin Allocation of the Fieldbus Interface
28
Connecting the Fieldbus
28
Field Bus Connection with Terminating Resistors
31
Pin Assignment of Power Supply
32
3 Commissioning as Function Module F24
33
General Information on Commissioning
33
Configuration and Addressing
33
Number of Inputs/Outputs
33
Addressing Rules
35
Addressing Examples (Examples of Address Assignment)
37
Address Assignment after Extension/Conversion
42
CC-Link Memory Mapping
42
Fieldbus Configuration
44
Parameterisation
45
Parameters of the CPX Terminal
46
Parameterisation Concepts
47
Commissioning of the CPX Terminal on the Fieldbus
48
HOLD/CLEAR and Fail Safe
48
RUN/PAUSE and STOP of the Master
48
RAS Function
48
Operation as Function Modules F24 to CC-Link Master Version
49
4 Diagnostics and Error Handling
50
General Notes on Diagnostics and Error Handling
50
Overview of Diagnostics Options
51
Error Messages of the Bus Node CPX-FB23-24
52
Diagnostics Via Leds
53
Normal Operating Status
54
CPX-Specific Leds
55
CC-Link-Specific Leds
57
Possible Operating States of CC-Link-Specific Leds
58
Diagnostics Via Field Bus CC-Link
59
Status Bits
59
I/O Diagnostic Interface
60
5 Function Module F23
61
General Instructions
61
Installation
61
Setting the Number of Stations Per Slave / Number of I/O Bytes
62
Commissioning
63
Configuration and Addressing
63
Bus Node
69
Address Assignment after Extension/Conversion
71
CC-Link Memory Mapping
71
Fieldbus Configuration
74
Parameterisation
74
Commissioning of the CPX Terminal on the Fieldbus
74
RUN/PAUSE and STOP of the Master
75
General Notes on Diagnostics and Error Handling
75
A Technical Appendix
76
Technical Data
76
Default Parameterisation
77
Accessories
78
B Glossary
79
List of Abbreviations
79
Advertisement
Advertisement
Related Products
Festo CPX-FB32
Festo CPX-FB23-24
Festo CPX-FB39
Festo CPX-FB40
Festo CPX-FB14
Festo CPX-FB6
Festo CPX-F8DE-P
Festo CPX-FVDA-P2
Festo CPX-FVDA-P
FESTO CPX-4AE-P-D10
Festo Categories
Industrial Equipment
Control Unit
Controller
Touch terminals
DC Drives
More Festo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL