Deutz Engine - D2011; Glow Plugs; Check Oil Level - JLG 400S Service And Maintenance Manual

Table of Contents

Advertisement

4. Catch any escaping fuel.
5. Clean dirt from filter carrier sealing surface.
6. Apply light film of oil or diesel fuel to rubber gasket of
new filter cartridge.
7. Screw in new filter by hand until gasket is flush. Hand-
tighten filter another 3/4 turn.
8. Check for leaks.
3121671
SECTION 3 - CHASSIS & TURNTABLE

3.21 DEUTZ ENGINE - D2011

NOTE: Refer to engine manufacturer's manual for detailed oper-
ating and maintenance instructions. Limited engine main-
tenance items are presented here for convenience but
detailed engine maintenance items and schedule are
included in the engine manufacturer's manual.

Glow Plugs

If the glow plug option is enabled in the JLG Control System,
the glow plug and indicator lamp will be energized when the
Power/Emergency Stop switch is pulled on if the ambient air
temperature is less than 50° F (10° C) and the engine coolant
temperature is less than 140° F (60° C). This determination will
occur one second after the Power/Emergency Stop switch has
been pulled on. The lamp and glow plugs will remain ener-
gized for the period of time specified by the setting in the JLG
Control System. Engine start shall be disabled during this
period. On Deutz engines, the glow plugs will continue (post
glow) after the engine has started for three times the machine
digit setting.

Check Oil Level

1. Switch the engine off before checking oil level.
2. Make sure the machine and engine are level.
3. Remove the oil dipstick.
4. Wipe the dipstick with non-fibrous, clean cloth.